Plan Review Notes For Permit 03042225 |
Permit Number |
03042225 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-05-06 00:00:00 | MASTER PLAN 02081384 MODEL C-B-A-A-B-C | | | | *** ISSUED PERMIT*** | | -PLAN REVIEW HISTORY- | | | | PERMIT# 0304222503042238 | | 0304222703042239 | | 0304223003042242 | | ADDRESS:LOTS 257-261 | | CONT: CONTINENTAL HOMES | | TELL # (954)428-4854 | | | | THE ATTACHED COMMENTS ARE PART OF THE | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | *******BUILDING PROVISO***************** | | 1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | CODE OR A REFRENCED STANDARD SHALL NOT | | BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. | | RE-EVALUATE TRUSS LOAD TABLES BEFORE | | ROOF FRAMING INSPECTION!!!! | | JIM WITMER | | (561)805-6715 (NEW TELEPHONE NUMBER) |
|