2003-06-04 00:00:00 | ******CORRECTIONS******* |
| |
| SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| [email protected] |
| |
| 1.)SEE #2 ON PREVIOUS CORRECTION |
| LIST; ENERGY CALCS REQUIRED. |
| |
| 2.)SEPARATE PERMITS REQUIRED. |
| |
| 3.)FOR THE ATTACHMENTS OF THE NEW |
| SLAB TO THE EXISTING, SHOW THE LENGTH |
| OF THE DOWELS AND EMBEDMENT. |
| |
| 4.)THE CEILING INSULATION IS TO BE |
| R19 MINIMUM (FBC 13-404.1.C).IT WAS |
| CORRECT ON THE ORIGINAL PLAN, THEN WAS |
| CHANGED TO R11.CORRECTION #5 |
| REFERRED TO THE WALL INSULATION. |
| SPECIFY THE INSULATION R-VALUE FOR THE |
| WALLS. |
| |
| 5.)THE NOTE ABOVE THE BEAM PLAN ON THE |
| ROOF PLAN SHOWS 6" AND 8" EMBEDMENT. |
| CLARIFY.ALSO SAYS "INTO EX. CONC FTG". |
| ISN'T THIS FOR THE BEAM, NOT THE |
| FOOTING?IT IS ON THE ROOF PLAN. |
| |
| 6.)SEE PREVIOUS CORR. NOTE #7.THE |
| SHEATHING SCHEDULE STILL DOES NOT |
| COMPLY. |
| |
| 7.)THE ATTACHMENT OF THE NEW FOOTING |
| TO EXISTING SHOWS BOTH 6" AND 8" |
| EMBEDMENT.CLARIFY. |
| |
| 8.)TWO COPIES OF ALL PRODUCT APPROVALS |
| MUST BE SUBMITTED. |
| |
| 9.)THE ROOF PRODUCT APPROVAL IS TO |
| RE-COVER AN EXISTING DECK WITH AN |
| EXISTING ROOF.YOU MAY SUBMIT THE |
| CORRECT PRODUCT APPROVAL NOW OR SUBMIT |
| IT WITH THE ROOF PERMIT APPLICATION. |