Plan Review Notes For Permit 03041167 |
Permit Number |
03041167 |
|
Review Stop |
B |
Sequence Number |
12 |
|
Notes |
Date |
Text |
2004-03-24 00:00:00 | SHEETS RECEIVED IN THE CONSTRUCTION | | SERVICES DEPARTMENT HAVING A CAL | | ENGINEERING SHOP DRAWING REVIEW STAMP | | DATED 3/6/04 WITH AN INDISCERNIBLE | | INITIAL ARE NOT SATISFACTORY. | | | | THE SHEETS PROPOSE STRUCTURAL CHANGES | | AND OR REPAIRS AND ARE NOT SIGNED, | | SEALED AND DATED BY A FLORIDA | | PROFESSIONAL ENGINEER. | | | | ONE SET PROPOSES CUTTING PANEL P-20 FOR | | A DOOR.ANOTHER PROPOSES A SOLUTION FOR | | MISSED EMBED PLATES AND A THIRD | | DESCRIBES A METHOD FOR INSTALLING | | MISSED REBAR AT THE PANEL FLOOR SLAB | | CONNECTION. | | | | THE ARDAMAN & ASSOCIATES REPAIR METHOD | | FOR THE UNDERMINED SLABS WAS NOT | | EMPLOYED.PLEASE ADVISED ACCEPTANCE OF | | THE UNCOMPACTED FILL IN THESE AREAS. | | SEE ATTACHED PHOTOS. | | | | PROVIDE PLANS AND SKETCHES IN ACCORDANCE | | WITH GOOD ENGINEERING PRACTICE SUITABLE | | FOR PUBLIC RECORD. |
|