2003-04-29 00:00:00 | THESE WILL BE THRESHOLD BUILDINGS AND |
| MUST COMPLY WITH FBC 105.13 AND FS 553. |
| |
| SHEET S4.02 ARE THE THIRD THROUGH FIFTH |
| FLOORS TO BE ASSUMED THE SAME AS THE |
| SECOND?PLEASE CLARIFY DESIGN INTENT |
| THROUGHOUT, INCLUDING THE ARCHITECTURAL |
| PAGES.SEE FBC 104.2 AND THE LIST IN |
| FBC 104.3.1.1 FOR PERMIT PLAN |
| INFORMATION. |
| |
| SHEET S3.01, HOW WERE THE COMPONENT AND |
| CLADDING PRESSURES OF +33.7 AND -44.0 |
| DETERMINED FOR BUILDINGS OF THIS |
| HEIGHT. |
| |
| WILL THERE BE ANY TEST REQUIEMENTS OF |
| THE REINFORCED MASONRY? |
| |
| SHEET S3.02 DECLARES A 130 MPH WIND |
| SPEED, WEST PALM BEACH IS IN AN 140 MPH |
| ZONE. |
| |
| SHEET S3.02 CITES COMPONENT AND CLADDING |
| PRESSURES FROM FIGURE (TABLE) 1606.2B. |
| IT APPEARS THE FACTORS FROM 1606.2D |
| HAVE NOT BEEN APPLIED AND THE ZONES |
| SHOWN ON SHEET S3.01 ARE NOT CORRECT |
| FOR THESE BUILDINGS.FURTHER, THESE |
| BUILDINGS DO NOT APPEAR TO HAVE THE |
| SYMMETRY OF A SIMPLE DIAPHRAGM BUILDING |
| AS PROVIDED FOR IN FBC 1606.2.1 AND |
| SHOULD BE DESIGNED TO THE WIND |
| PROVISIONS OF ASCE 7-98. |
| |
| THE WOOD TRUSS NOTES ON S3.01 CITE AN |
| NDS STANDARD FOR DESIGN.SEE FBC |
| 2309.2 FOR MANDATORY DESIGN |
| SPECIFICATIONS AND FBC TABLE 1604.1 FOR |
| MINIMUM LIVE LOAD REQUIREMENTS. |
| |
| SHEET A9.01, THE STAIR DOORS SHOWN AS |
| #15 ARE REQUIRED TO BE 90 MINUTE, SEE |
| FBC TABLE 705.1. |
| |
| DRAFTSTOPPING OF THE ATTIC SPACE IN |
| ACCORDANCE WITH FBC 2305.2.3 IS |
| REQUIRED. |
| |
| SHOW THE ATTIC ACCESS, FBC 2309.6 AND |
| VENTILATION REQUIREMENTS OF FBC 2309.7, |
| INCLUDE FREE AREA OF ANY SCREEN VENTS. |
| |
| SHOW THE DESIGN LOADS FOR THE HAND AND |
| GUARD RAILS.SEE FBC 1608.2. |
| |
| BEFORE A PERMIT TO CONSTRUCT MAY BE |
| ISSUED IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY THE PERMIT PLANS STAMPED |
| BY THAT OFFICE AND A COPY OF THE PAID |
| RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. CALL 561-233-5025 FOR MORE |
| INFORMATION. |
| |
| IF PRODUCT ACCEPTANCE AND/OR TEST |
| REPORTS FOR THE DOORS, WINDOWS AND ROOF |
| COVERINGS ARE NOT INCLUDED WITH THE |
| PERMIT APPLICATION, SEPARATE PERMITS |
| AND ADDITIONAL FEES WILL BE REQUIRED. |
| |
| PERMIT INFORMATION, PLANS, |
| SPECIFICATIONS, ETC. ARE TO BE PROVIDED |
| TO THE CITY IN TRIPLICATE FOR THRESHOLD |
| BUILDINGS. |