2003-05-12 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SUBMIT THE RECEIPT FOR THE COUNTY
 IMPACT FEES.
  
 3) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMENDMENTS TO THE FBC
 1804.2.2.
  
 4) REVISE ITEM #7 UNDER STUCCO SPECS. ON
 A-3 TO REQUIRE FASTENING AT EVERY RIB
 (4"O.C.) AS REQUIRED BY ASTM C 1063.
 ITEMS #4 AND #5 ARE THE SAME NOTE.
  
 5) THE CONDITIONED AREA ON THE ENERGY
 CALCULATIONS IS 2292 SQFT AND THE PLANS
 LIST 2260 SQFT OF A/C SPACE. PLEASE
 CORRECT.
  
 6) REVISE THE TRUSS CONNECTOR UPLIFT
 VALUES TO VALUES THAT DO NOT INCLUDE THE
 STRESS INCREASE ON THE STEEL CALCS.
 WHICH ARE NO LONGER ALLOWED BY THE FBC.
  
 7) SUBMIT PRODUCT APPROVALS FOR A SINGLE
 OUTSWING DOOR WITH SIDELITE.
  
 8) THE OWNER OF RECORD INDICATED ON THE
 PERMIT APPLICATION IS INTELLI HOMES,
 HOWEVER THE COUNTY PROPERTY APPRAISER
 AND THE CITY RECORDS LIST TIDES PALM
 BEACH LTD PARTENERSHIP AS THE OWNER.
 PLEASE CORRECT.
  