2003-05-28 00:00:00 | CHECKLIST: |
| 1-PROVIDE COPY OF THE SOIL TEST REPORT. |
| 2-ENERGY CALCULATIONS NEED TO BE SITE |
| SPECIFIC OR CALCULATED FOR THE WORST |
| CASE SCENARIO. REVISE AS REQUIRED. |
| 3-NEED TO UPDATE WORKER'S COMPENSATION |
| INSURANCE. |
| 4-PAY IMPACT FEES AND FILE NOTICE OF |
| COMMENCEMENT. |
| 5-SPECIFICATIONS FOR FIREBLOCKING DON'T |
| APPLY ONLY TO CONCEALED SPACES UNDER |
| STAIRS, BUT TO ALL CONCEALED SPACES |
| IN THE BUILDING. SEE SEC. 2305 FBC |
| 2001 AND REVISE AS REQUIRED. |
| 6-SHEET A-6: A)REVISE HANDRAIL HT. SEE |
| SEC. 1007.5.1 FBC 2001. |
| B)THERE ARE NOT SPECS FOR RISER HEIGHT. |
| SEE SEC. 1007.3.1 (EXCEPTION #1). |
| C)TYPICAL TWO STORY WALL SECTION IS |
| MISSING ALL THE CONNECTORS TOP & BOTT. |
| FOR 2X FRAMED WALL. SEC. 104.2.1.2 |
| CITY AMENDMENTS TO FBC 2001. |
| **NEED 7/8" MIN. STUCCO THICKNESS AS |
| REQUIRED BY ASTM C-926. |
| **REVISE WALL SHEATHING THICKNESS. SEE |
| DIAPHRAGM SCHEDULE ON SHEET A-9. |
| **SEE PLANS FOR ADDITIONAL COMMENTS. |
| 7-CLARIFY WHAT IS THE DETACHABLE SAFETY |
| RAIL SPECIFIED ON ELEVATION ON SHEET |
| A-4 AND WHERE IS IT GOING TO BE |
| INSTALLED. SEC. 104.2.1.2 CITY AMENDM. |
| 8-UPDATE TRUSS SCHEDULE. 33% ALLOWABLE |
| STRESS INCREASE IS NOT ALLOWED BY SEC. |
| 1609.4.3 FBC 2001. SEE USP 2003 |
| CATALOGUE WITH REVISED LOADS AND |
| REVISE AS REQUIRED. |
| 9-PROVIDE COMPLETE DETAILS & STRUCTURAL |
| INFORMATION FOR PRECAST GUARDRAIL |
| INSTALLATION. DETAIL PROVIDE IS NOT |
| COMPLETE. SEE SEC. 1608.2.2 FBC 2001. |
| 10-FOUNDATION PLAN: CLARIFY FOOTING AT |
| GARAGE INTERIOR BEARING WALL. IS IT |
| F8 OR TE-17? SEE PLAN. |
| 11-THERE ARE SOME CONNECTORS THAT ARE NO |
| SPECIFIED. SEE FRAMING PLAN FOR |
| COMMENTS. SEC. 104.2.1.2 CITY AMENDM. |
| 12-FRAMING DETAIL FOR ARCHED OPENINGS |
| NEED TO HAVE 2X BLOCKS, NOT 1X BLOCKS |
| TO PROVIDE STRUCTURAL SUPPORT FOR |
| WINDOW. SEC. 104.2.1.2 CITY AMENDMENTS |
| TO FBC 2001. |