Plan Review Notes
Plan Review Notes For Permit 03032205
Permit Number 03032205
Review Stop P
Sequence Number 2
Notes
Date Text
2003-05-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 COMMENTS FROM PREVIOUS REVIEW NOT ADD-
 RESSED. SEE NEW SHT P-1.1
 1) SHT P-1.1 DISHWASHER SHALL DRAIN INTO
 SANITARY NOT GREASE WASTE. UTILITY ORD.
 2) ALL ABANDONED/CAPPED PIPES SHALL BE
 INSPECTED PRIOR TO COVERING.
 3) SHT P-1.1, 3 COMPARTMENT SINK SHALL
 DRAIN TO GREASE WASTE.
 4) SHT P-1.1 ALL INDIRECT WASTE SHALL
 DRAIN TO FLOOR SINKS. SEC 802.3 - FLOOR
 DRAINS ARE NOT AN APPROVED INDIRECT
 WASTE RECEPTOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692