2003-04-16 00:00:00BUILDING PLAN REVIEW
 CONTINUED 4/16/03
  
 19) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 20) 1707.4.5.2 MULLIONS SHALL BE
 DESIGN-ED TO TRANSFER THE DESIGN
 PRESSURE LOADSAPPLIED BY THE WINDOW OR
 DOOR ASSEMBLIESTO THE ROUGH OPENING
 SUBTRATE.
  
 21)1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND
 TEST-ED FOR A PERIOD EQUAL TO THE
 QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
 PRESSURE. DADE COUNTY & SBCCI REPORTS
 ARE ACCEPTED.
  
 22)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. SEE ATTACHMENT.
  
 23) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 24) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE
 ANCHORED IN ACCORDANCE WITH THE
 PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS
 DEMONSTRA-TED BY ACCEPTED ENGINEERING
 PRACTICES.
  
 25) SECTIONS; 103.6, 1606.4, 1707.4
 WPB IMPLEMENTATION STANDARD FOR HURRI-
 CANE MISSLE IMPACT STANDARD, QUESTION
 # 14, ARE REMOVABLE STORM PANELS APPRO-
 PRIATE FOR USE ON VERY LARGE, MID OR
 HIGH-RISE STRUCTURES? NO, EXCEPT ON THE
 GROUND FLOOR. ON COMMERCIAL AND MULTI-
 UNIT RESIDENTIAL STRUCTURES, ABOVE THE
 FIRST LEVEL, IMPACT RESISTANT OR
 PERMANENTLY AFFIXED PROTECTIVE DEVICES
 SHALL
 REQUIRE THE WRITTEN APPROVAL OF THE
 BUILDING OFFICIAL.
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE
 USEDFOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE
 INSTALLATIONSCHEDULE SUMMARIZING &
 IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL
 PRES-SURE ZONES, SLAT TYPES, ETC.,
 SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 26) SHEET S-5.1 STRUCTURAL NOTE (9):
 BALCONY / TERRACE RAILINGS & STAIR
 RAIL-INGS SHALL BE DESIGNED TO RESIST A
 LOAD OF 50 LBS. APPLIED IN ANY
 DIRECTION,
 (1608.2.2.2) THIS SECTION REFERS TO
 GAURD RAILS WITHIN DWELLING UNITS.
 1608.2.2.3 REFERS TO EXTERIOR GUARD
 RAILSYSTEMS, BEING ABLE TO RESIST A 200
 LB
 CONCENTRATED HORIZONTAL LOAD APPLIED ON
 A 1 SQ FT AREA AT ANY POINT IN THE
 SYSTEM INCLUDING INTERMEDIATE RAILS OR
 OTHER ELEMENTS SERVING THIS PURPOSE.
  
 27) SHEET S-1.38 PREFAB METAL TRUSS
 CON-NECTIONS SEE SCHEDULE "D,E& F" THE
 2003 USP CATOLOG, FORMULTIPLE ANCHOR
 INSTAL- LATIONS NOTE: MULTIPLE
 INSTALLATIONS NOTCLOSER THAN 8", A
 DERATING FACTOR WILL
 BE REQUIRED BECAUSE CONE FAILURE.
 *****NEW IN FL CODE****
 1609.4.3 LOAD REDUCTIONS!!!!!
  
 28) SHEET A-1 GENERAL NOTES: 34 MINIMUM
 FLAME SPREAD TO BE IN CONFORMANCE WITH,
 ID-11.1 INTERIOR FINISHES, NO INFORMA-
 TION ABOUT TABLE 803.3 FLAME SPREAD/
 SMOKE DEVELOPMENT.
 TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 29) EXTERIOR WALLS PRESSURE TREATED
 FURRING ALLOWED IF THE FOLLOWING
 REQUIREMENTS ARE MET, 803.9.1.
  
 30) INTERIOR WALLS, BACKING TO BE NON-
 COMBUSTIBLE MATERIAL OR FIRE RETARDANT
 TREATED WOOD. 609.2.1.
  
 31) GYMNASIUM AN A-2 SMALL ASSEMBLY,
 INDICATE 2 HR WALLS W/ 1 1/2 HR PROTEC-
 TIVES.
  
 32) GYMNASIUM REQUIRES 2 MEANS OF
 EGRESS11-4.1.3 (9) IN A BUILDING OR
 FACILITIESOR PORTION S OF BUILDINGS OR
 FACILITIES REQUIRED TO BE ACCESSIBLE,
 ACCESSIBLE
 MEANS OF EGRESS SHALL BE PROVIDED IN
 THESAME NUMBER AS REQUIRED BY THE LOCAL
 BUILDING LIFE SAFETY REGULATIONS.
 THE GYM DOES HAVE 2 EXITS BUT ONLY
 ONE IS ACCESSIBLE!!!
  
 33) GYMNASIUM EGRESS DOORS, 1019.7.2
 EACH DOOR IN A MEANS OF EGRESS FROM AN
 AREA OF A GROUP A OCCUPANCY MAY BE PRO-
 VIDED WITH A LATCH OR LOCK ONLY IF IT
 ISPANIC HARDWARE OR FIRE EXIT HARDWARE,
 WHICH RELEASES WHEN 15 LBS IS APPLIED
 TOTHE RELEASING DEVISE. THIS DOOR ALSO
 INDICATES A CARD READER, PROVIDE
 INFORMATION FOR FAIL SAFE RELEASE?
  
 34) SHEET A-3-5DA STAIRWELL # 1, HAS A
 ROOMIN THE STAIRWELL, NO DESIGNATION?
 IS THIS A AREA OF REFUGE? INACCESSIBLE
 TO HANDICAPPED PEOPLE!
 STAIWELL# 1 HAS NO DOOR AT THE END
 OF THE VERTICAL SECTION, TO CONTINUE
 THERATING OF 2 HRS,ALSO SEE 1006.1.3.1
 FOR WHAT IS ALLOWABLE IN THE STAIRWELL.
  
 35) 705.2.4.3 REFUSE CHUTE ACCESS ROOMS.
 ACCES OPENINGS FOR REFUSE CHUTES SHALL
 BE LOCATED IN ROOMS OR COMPARTMENTS
 COMPLETELY ENCLOSED BY CONSTRUCTION &
 OPENING PROTECTIVES IN ACCORDANCE WITH
 TABLE 705.1.2. ACCESS OPENINGS TO REFUSE
 CHUTES SHALL NOT BE LOCATED IN EXIT
 ACCESS CORRIDORS OR EXIT ENCLOSURES.
 ***SHEETA-3-6AB***
 36) ELEVATOR LOBBY VS ENTRY DOOR TO
 SUITE, COMMON TO ALL FLOORS.
 412.6.3 REVIEW WHAT DORS AREN'T ALLOWED
 IN ELEVATOR LOBBIES, GUEST ROOM DOOR
  
 37)SAME SHEET GRID 8/C, STORAGE UNIT,
 WHAT TYPE OF STORAGE, S1 OR S2?
 WALL RATING?
  
 38) UNIT H210 BALCONY DETAIL 3/A8.11
 NO SUCH DETAIL?
  
 39) SHEET A-8.12 GUARDRAILS: WITHIN
 INDIVIDUAL LIVING UNITS OR GUEST ROOMS
 MAY BE 36",1026.5.1.
 EXTERIOR GUARDRAIL HEIGHT,MINIMUM IS
 42"1015.2.
 1015.3 OPENINGS: SO A 4" SPHERE CAN NOT
 PASSTHROUGH ANY OPENING. A BOTTOM RAIL
 OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER SPHERE
  
 40) STAIRWAY GUARDRAILS 1015.3 SEE
 EXCEPTION (1) A 6" SPHERE SHALL NOT
 PASSTHROUGH THE TRIANGLE OPENING FORMED
 BY
 A TREAD, RISER AND BOTTOM OF A GUARDRAIL
 SEE A-10.07 DETAIL #2.
  
 41) SHEET A-10.02 DETAILS 1 & 6
 RE: EXPANDED POLYSTYRENE MOLDING, THIS
 MATERIAL IS NOT ALLOWED IN THE FIRE
 DISTRICT. SEE F 102.2.7 ARCHITECTURAL
 TRIM ON BUILDINGS LOCATED IN THE FIRE
 DISTRICT SHALL BE CONSTRUCTED OF
 APPROVED NONCOMBUSTIBLE MATERIALS OR
 FIRE RETARDANT TREATED WOOD.
  
 THIS SESSION OF PENEMATION WILL NOT
 EXCEPT MORE THAN 200 LINES, A THIRD
 BUILDING REVIEW WILL NEED TO BE OPENED.
 THE SAME SIZE AS ROOF DRAINS, INSTALLED
 WITH THE INLET FLOW LINE LOCATED 2"
 ABOVE THE LOWEST POINT OF THE ROOF LINE.
 OVERFLOW SCUPPERS SHALL BE A MINIMUM OF
 4"IN HEIGTH AND SHALL BE PLACED IN WALLS
 OR PARARETS WITH THE INLET FLOW LINE
 NOT LESS THAN 2" ABOVE THE ROOF SURFACE.