Plan Review Notes For Permit 03031046 |
Permit Number |
03031046 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-06-23 00:00:00 | ******CORRECTIONS******* | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)TRUSS CONNECTOR UPLIFT SPECIFIED | | ON THE PLAN EXCEED MAXIMUM VALUES | | ALLOWED IN THE CATALOG; REFER TO USP | | 2003 CATALOG. |
|