Plan Review Notes
Plan Review Notes For Permit 03030699
Permit Number 03030699
Review Stop E
Sequence Number 2
Notes
Date Text
2003-08-19 00:00:00*************** UNSAT **************
  
 1)NOTE: PLEASE COMPLETE RISER DIAGRAM
 TO INCLUDE PANEL.
  
 2)NOTE: PLEASE VERIFY SIZE OF PANEL,
 SERVICE CONDUCTORS ARE SHOWN FOR A 200A
 SERVICE?
  
 3)NOTE: PLEASE SEE THAT WASHER IS SHOWN
 AS OPTIONAL? PLEASE SEE 220.16 AND
 FBC/PLUMB. WASHER IS REQ'D AND MUST BE
 AVAILABLE.
  
 4)NOTE: PLEASE SEE GROUNDING ELECTRODE
 CONDUCTOR, NOTE TO HOUSE STEEL, PLEASE
 SEE 250.50, THIS SHOULD NOTE TO FOOTER
 STEEL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]