2003-03-04 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 1} PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED,
 DATEDAND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
  
 2} PLEASE NOTE THAT TWO SETS OF PLANS
 ARE REQUIRED FOR REVIEW.
  
 3} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
  
 4} PLEASE LIST THE REQ`D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 5} NFPA-72 8-1.4.2 PROHIBITS SMOKE
 DETECTORS IN THE KITCHEN. A HEAT
 DETECTOR IS ACCEPTABLE AND MEETS THE
 INTENT OF 8-1.4.1.6(2).
  
 6} PLEASE INDICATE IF THE GARAGE IS TO
 REMAIN OR BE TURNED INTO LIVING SPACE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  