Plan Review Notes
Plan Review Notes For Permit 03021563
Permit Number 03021563
Review Stop B
Sequence Number 2
Notes
Date Text
2003-04-25 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE STRUCTURE IS LOCATED IN AN A5
 FLOOD ZONE AN ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 3) SEPARATE PERMITS WILL BE REQUIRED FOR
 THE POOL. THE SOIL REPORT FOR THE POOL
 AND APPROVAL FROM PLANNING DEPT. SHOULD
 BE SUBMITTED AT THAT TIME.
  
 4) THE SOIL BEARING TEST REPORT STATES
 THAT A SECOND STORY IS BEING ADDED TO AN
 EXISTING STRUCTURE. THE PLANS AND
 APPLICATION FOR PERMIT STATE THAT THE
 EXISTING STRUCTURE IS BEING DEMOLISHED
 (INCLUDING THE FOUNDATION) AND THAT A
 NEW TWO STORY RESIDENCE AND GARAGE/APT
 ARE TO BE BUILT. PLEASE CLARIFY. THE
 SOIL REPORT GIVES THE BEARING CAPACITY
 OF THE SOIL AS 1750 PSF AND THE
 STRUCTURAL PLANS REQUIRE 2500 PSF. THE
 SOIL REPORT ALSO INDICATES POSSIBLE
 SETTLEMENT OF UP TO ONE INCH. HAS THIS
 BEEN CONSIDERED IN THE DESIGN OF THE
 STRUCTURES.
  
 5) PROVIDE A SOIL BEARING TEST FOR THE
 GARAGE/APARTMENT.
  
 6) PROVIDE A CONSTRUCTION DETAIL FOR THE
 ARCHES AT THE B1 BEAMS OF THE BALCONIES.
 INDICATE THE LOCATION AND SIZE OF THE
 STEEL REINFORCING IF THEY ARE POURED
 CONCRETE.
  
 7) STRUCTURAL SHEET 2 SPECIFIES 1/2" X
 5" WEDGE ANCHORS TO FASTEN THE DOUBLE
 2 X 10 LEDGERS TO THE BEAM AT THE
 BALCONIES. PLEASE REVIEW THIS FOR
 ADEQUATE EMBEDMENT DEPTH.
  
 8) STRUCTURAL SHEET 2 ALSO INDICATES
 FLOOR TRUSSES AT THE FOYER WHICH IS OPEN
 TO SECOND FLOOR CEILING. PLEASE CORRECT.
  
 9) INDICATE THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES AT THE WINDOW AND
 DOOR OPENINGS OF THE GARAGE/APARTMENT.
  
 10) THE POSITIVE AND NEGATIVE WINDLOAD
 PRESSURES THAT WERE RED LINED ON SHEETS
 A-3.0 AND A-3.1 NEED TO BE INITALED AND
 DATED BY THE DESIGNER OF RECORD.
  
 11) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - WOOD FRONT DOOR
 - 3/4 HOUR FIRE RATED DOOR
 - OVERHEAD GARAGE DOOR
  
 12) THE PRODUCT APPROVALS SUBMITTED FOR
 THE FRENCH DOORS AND THE TOWN AND
 COUNTRY STORM PANELS ARE EXPIRED. PLEASE
 SUBMIT CURRENT APPROVALS.(THE NEW REPORT
 FOR THE STORM PANELS IS #2304.)
  
 13) SUBMIT MANUFACTURER'S SPECS. AND
 LISTING INFORMATION FOR THE PREFAB
 FIREPLACE UNDER SEPARATE PERMIT AS
 INDICATED BY THE ARCHITECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202