Date |
Text |
2003-03-10 00:00:00 | PLEASE PROVIDE A RECENT SIGNED AND |
| SEALED PROPERTY SURVEY. |
| |
| BEFORE A PERMIT TO CONSTRUCT MAY BE |
| ISSUED IMPACT FEES MUST BE PAID TO THE |
| COUNTY THE PERMIT PLANS STAMPED BY THAT |
| OFFICE AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICTION. |
| CALL 561-233-5025 FOR MORE INFORMATION. |
| |
| THIS NEW CONSTRUCTION WILL CREATE TWO |
| ZERO LOT LINE BUILDINGS ON THE SAME |
| PROPERTY.SHOW THE EXISTING BUILDING |
| WALL THAT IS ADJACENT TO THE PROPOSED |
| BUILDING AS HAVING A THREE HOUR FIRE |
| RATING, (TYPEV CONSTRUCTION) AND NO |
| OPENINGS FOR ITS FULL HEIGHT OR |
| MODIFICATIONS TO EFFECT THOSE |
| CONDITIONS.SEE FBC TABLE 600. |
| |
| SHEET SP1.SHOW THE CONSTRUCTION |
| DETAILS FOR THE NEW HC RAMP, THE SIGN |
| FOR THE HC PARKING SPACE, AND THE |
| APPROPRIATE STRIPING FOR THE HC PARKING |
| SPACE.SEE FBC 11-4. |
| |
| SHEET A3, THE "TIE COLUMN BRACE DETAIL" |
| WHERE IS THAT USED? |
| |
| THIS BUILDING WILL BE LOCATED IN THE |
| DESIGNATED FIRE DISTRICT AND WILL |
| REQUIRE TWO HOUR FIRE RATED EXTERIOR |
| WALLS ON THENORTH, SOUTH AND EAST |
| ELEVATIONS.SEE FBC F102.2.6 AS |
| AMENDED BY THE CITY. |
| |
| SHOW A CONSTRUCTION DETAIL AND DESIGN |
| LOAD FOR THE PALLET RACKS SHOWN ON |
| SHEET A1.SEE FBC 104.2 |
| |
| WHAT IS THE NATURE AND QUANTITY OF THE |
| COMMODITIES TO BE STORED IN THIS |
| BUILDING?SEE FBC 104.2 |
| |
| SHEET A4 ROOF FRAMING.SHOW THE JOIST |
| DESIGNATIONS FROM THE 1997 SJI SPECS. |
| SHOW THE END SUPPORT CONNECTION, |
| AND UPLIFT |
| REQUIREMENTS. SEE FBC 104.2. |
| |
| DEMONSTRATE COMPLIANCE WITH FBC 1803.2 |
| FOR THE FOUNDATION WHERE APPLICABLE. |