Plan Review Notes
Plan Review Notes For Permit 03012452
Permit Number 03012452
Review Stop B
Sequence Number 2
Notes
Date Text
2003-05-13 00:00:00******CORRECTIONS*******
  
 1.)FOUR SHEETS OF 2B WERE SUBMITTED;
 TWO ARE UNSEALED.UNSURE AS TO WHY TWO
 EXTRA COPIES WERE SUBMITTED BUT THEY
 NEED TO BE SIGNED AND SEALED IF THEY ARE
 TO BE A PART OF THE PERMIT PACKAGE.
  
 2.)PROVIDE A LICENSE NUMBER FOR THE
 ARCHITECT; HAVE HIM SIGN,SEAL & DATE THE
 PLAN AS HIS TITLE BLOCK IS ON THE PLAN.
  
 3.)SEPARATE PERMITS REQUIRED;ELECTRIC,
 PLUMBING, MECHANICAL, ROOFING.
  
 4.)A NOTICE OF COMMENCEMENT IS
 REQUIRED TO BE FILED WITH THE CLERK OF
 COURTS BEFORE A PERMIT CAN BE ISSUED.
  
 5.)SEE PREVIOUS CORRECTION NOTICE,
 ITEM #1.SUBMIT PRODUCT APPROVALS FOR
 THE MULLIONS, GARAGE DOOR, AND 3'0X6'8
 DOOR.
  
 6.)IF YOU MAKE CHANGES TO A SEALED
 DRAWING IN INK, THE CHANGES MUST BE
 INITIALED BY WHOEVER SEALS THE PLAN.
  
 7.)FBC 1606.1.7, INFORMATION REQUIRED
 TO BE ON DRAWINGS.
  
 8.)CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC, 2111.1.9 'WHERE EXTERIOR
 WALL MASONRY UNITS BEAR ON A CONCRETE
 FLOOR SURFACE, A 1.5 INCH RECESS SHALL
 BE PROVIDED TO MINIMIZE WATER INTRUSION
 INTO FINISHED AREA.'
  
 9.)ENERGY CALCS REQUIRED FBC13-101.2.
  
 10.)FBC 2307.1.1, SILL ANCHORAGE TO
 HAVE A MINIMUM EMBEDMENT OF 7".
  
 11.)FIRESTOP REQUIRED FBC 705.3.
  
 12.)PROVIDE NUMBER OF SOFFIT VENTS
 REQUIRED WITH SIZES.
  
 13.)ATTIC ACCESS REQUIRED FBC 2309.
  
 14.)AREA CALCULATIONS SHOULD SHOW A
 TOTAL OF LIVING SPACE, AND A TOTAL OF
 NON-A/C SPACE, NOT SHOW CALCS BY FLOOR.
  
 15.)PROVIDE ROOF SHEATHING ATTACHMENT
 SCHEDULE, CITY OF WPB AMENDMENTS TO
 THE FBC, TABLE 2306.1.
  
 16.)FBC 1403.1.6, 6" CLEARANCE FROM
 EXTERIOR WALL COVERING TO EARTH.
  
 17.)PROVIDE ATTACHMENT UPLIFT
 INFORMATION.
  
 18.)THE SITE PLAN SHOWS A NEW
 DRIVEWAY, SLAB ON THE NORTH SIDE OF THE
 PROPERTY, AND ADDITIONS TO THE FRONT
 AND REAR OF THE EXISTING HOUSE.REVISE
 TO REFLECT THE WORK TO BE PERFORMED
 UNDER THIS PERMIT.THE TRUSS PLANS
 SHOW WORK FOR THE ADDITION TO THE
 EXISTING HOUSE.
  
 19.)THE PREVIOUS CORRECTION LIST #3,
 SUBMIT DETAILED DRAWINGS OF THE STAIRS,
 WAS NOT ADDRESSED. ONLY DRAWINGS FOR THE
 LANDING WERE GIVEN.STAIRS AND HANDRAIL
 TO COMPLY WITH FBC 1007.
  
 20.)REFERENCE THE LANDING DETAIL;
 IN REGARDS TO THE POST TO BE
 EMBEDDED 2' INTO THE GROUND, IS THAT
 FOR THE SHORT POST AT THE BASE OF THE
 STAIRS, OR THE TALL POST GOING TO THE
 TOP OF THE STAIRS, OR BOTH?WILL THERE
 BE ANYTHING STABILIZING THE POSTS IN
 THE GROUND (STEEL THROUGH THE BASE,
 CONCRETE)?
  
 21.)ANY CHANGES TO THE PLAN MUST GET
 HISTORIC APPROVAL.CHANGES WERE DRAWN
 IN FOR WINDOW SIZE AND CHANGING SINGLE
 WINDOWS TO DOUBLE.AFTER MAKING THE
 CHANGES TO THE PLAN, CLOUDED, TAKE BACK
 TO HISTORIC TO BE STAMPED.
  
 WHEN RESUBMITTING, PLEASE ASSEMBLE TWO
 COMPLETE PLAN SETS, IN ORDER.OLD
 SHEETS ARE TO BE BOUND SEPARATELY.
 MAKE A NOTATION ON THIS LIST AS TO HOW
 EACH ITEM HAS BEEN ADDRESSED IN ORDER
 TO EXPEDITE PLAN REVIEW.CLOUD CHANGES
 MADE TO THE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]