2003-05-13 00:00:00 | ******CORRECTIONS******* |
| |
| 1.)FOUR SHEETS OF 2B WERE SUBMITTED; |
| TWO ARE UNSEALED.UNSURE AS TO WHY TWO |
| EXTRA COPIES WERE SUBMITTED BUT THEY |
| NEED TO BE SIGNED AND SEALED IF THEY ARE |
| TO BE A PART OF THE PERMIT PACKAGE. |
| |
| 2.)PROVIDE A LICENSE NUMBER FOR THE |
| ARCHITECT; HAVE HIM SIGN,SEAL & DATE THE |
| PLAN AS HIS TITLE BLOCK IS ON THE PLAN. |
| |
| 3.)SEPARATE PERMITS REQUIRED;ELECTRIC, |
| PLUMBING, MECHANICAL, ROOFING. |
| |
| 4.)A NOTICE OF COMMENCEMENT IS |
| REQUIRED TO BE FILED WITH THE CLERK OF |
| COURTS BEFORE A PERMIT CAN BE ISSUED. |
| |
| 5.)SEE PREVIOUS CORRECTION NOTICE, |
| ITEM #1.SUBMIT PRODUCT APPROVALS FOR |
| THE MULLIONS, GARAGE DOOR, AND 3'0X6'8 |
| DOOR. |
| |
| 6.)IF YOU MAKE CHANGES TO A SEALED |
| DRAWING IN INK, THE CHANGES MUST BE |
| INITIALED BY WHOEVER SEALS THE PLAN. |
| |
| 7.)FBC 1606.1.7, INFORMATION REQUIRED |
| TO BE ON DRAWINGS. |
| |
| 8.)CITY OF WEST PALM BEACH AMENDMENTS |
| TO THE FBC, 2111.1.9 'WHERE EXTERIOR |
| WALL MASONRY UNITS BEAR ON A CONCRETE |
| FLOOR SURFACE, A 1.5 INCH RECESS SHALL |
| BE PROVIDED TO MINIMIZE WATER INTRUSION |
| INTO FINISHED AREA.' |
| |
| 9.)ENERGY CALCS REQUIRED FBC13-101.2. |
| |
| 10.)FBC 2307.1.1, SILL ANCHORAGE TO |
| HAVE A MINIMUM EMBEDMENT OF 7". |
| |
| 11.)FIRESTOP REQUIRED FBC 705.3. |
| |
| 12.)PROVIDE NUMBER OF SOFFIT VENTS |
| REQUIRED WITH SIZES. |
| |
| 13.)ATTIC ACCESS REQUIRED FBC 2309. |
| |
| 14.)AREA CALCULATIONS SHOULD SHOW A |
| TOTAL OF LIVING SPACE, AND A TOTAL OF |
| NON-A/C SPACE, NOT SHOW CALCS BY FLOOR. |
| |
| 15.)PROVIDE ROOF SHEATHING ATTACHMENT |
| SCHEDULE, CITY OF WPB AMENDMENTS TO |
| THE FBC, TABLE 2306.1. |
| |
| 16.)FBC 1403.1.6, 6" CLEARANCE FROM |
| EXTERIOR WALL COVERING TO EARTH. |
| |
| 17.)PROVIDE ATTACHMENT UPLIFT |
| INFORMATION. |
| |
| 18.)THE SITE PLAN SHOWS A NEW |
| DRIVEWAY, SLAB ON THE NORTH SIDE OF THE |
| PROPERTY, AND ADDITIONS TO THE FRONT |
| AND REAR OF THE EXISTING HOUSE.REVISE |
| TO REFLECT THE WORK TO BE PERFORMED |
| UNDER THIS PERMIT.THE TRUSS PLANS |
| SHOW WORK FOR THE ADDITION TO THE |
| EXISTING HOUSE. |
| |
| 19.)THE PREVIOUS CORRECTION LIST #3, |
| SUBMIT DETAILED DRAWINGS OF THE STAIRS, |
| WAS NOT ADDRESSED. ONLY DRAWINGS FOR THE |
| LANDING WERE GIVEN.STAIRS AND HANDRAIL |
| TO COMPLY WITH FBC 1007. |
| |
| 20.)REFERENCE THE LANDING DETAIL; |
| IN REGARDS TO THE POST TO BE |
| EMBEDDED 2' INTO THE GROUND, IS THAT |
| FOR THE SHORT POST AT THE BASE OF THE |
| STAIRS, OR THE TALL POST GOING TO THE |
| TOP OF THE STAIRS, OR BOTH?WILL THERE |
| BE ANYTHING STABILIZING THE POSTS IN |
| THE GROUND (STEEL THROUGH THE BASE, |
| CONCRETE)? |
| |
| 21.)ANY CHANGES TO THE PLAN MUST GET |
| HISTORIC APPROVAL.CHANGES WERE DRAWN |
| IN FOR WINDOW SIZE AND CHANGING SINGLE |
| WINDOWS TO DOUBLE.AFTER MAKING THE |
| CHANGES TO THE PLAN, CLOUDED, TAKE BACK |
| TO HISTORIC TO BE STAMPED. |
| |
| WHEN RESUBMITTING, PLEASE ASSEMBLE TWO |
| COMPLETE PLAN SETS, IN ORDER.OLD |
| SHEETS ARE TO BE BOUND SEPARATELY. |
| MAKE A NOTATION ON THIS LIST AS TO HOW |
| EACH ITEM HAS BEEN ADDRESSED IN ORDER |
| TO EXPEDITE PLAN REVIEW.CLOUD CHANGES |
| MADE TO THE PLAN. |
| |