2003-03-17 00:00:00**********CORRECTIONS************
  
 1.)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 2.)PLEASE NOTE ITEM #3 ON THE FIRST
 CORRECTION NOTICE.AS PER FBC3401.7.2.4
 THE REPLACEMENT OF OPERATIVE AND
 INOPERATIVE WINDOWS SHALL BE DESIGNED
 AND CONSTRUCTED IN ACCORDANCE WITH
 CHAPTER 16 OF THE FBC.HURRICANE
 PROTECTION REQUIRED.
  
 3.)PLEASE SUBMIT TWO COPIES OF ALL
 DOCUMENTATION.ONLY ONE COPY OF THE
 REVISED WINDOW SCHEDULE AND PRODUCT
 APPROVALS WAS SUBMITTED.
  
 4.)PROVIDE PRODUCT APPROVALS FOR THE
 PICTURE WINDOW FOR WINDOW #4.PRODUCT
 APPROVALS PREVIOUSLY SUBMITTED WERE FOR
 NORANDEX SINGLE HUNG AND NORANDEX
 FIXED WINDOW.LEGIBLE PRODUCT APPROVALS
 WERE REQUESTED (NOTE COMMENT #1 OF
 FIRST CORRECTION LIST).PGT SINGLE
 HUNG AND PGT MULLION PRODUCT APPROVALS
 WERE SUBMITTED.
  
 5.)A HOLD WAS PLACED ON THIS PROPERTY
 BY E.GARCED.PLEASE CONTACT MR. GARCED
 AT 659-8000, EXTENSION 8467.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-659-8096, EXTENSION 8340