Plan Review Notes For Permit 02121268 |
Permit Number |
02121268 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-01-03 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02121268 | | ADD: 714 23RD ST | | CONT: KENACO DEV | | TEL: (561)315-5077 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | *****PROVISO****** | | | | 1) STAIR GUARDRAIL 1015.3 OPENINGS | | OPEN GUARDRAILS SHALL HAVE INTERMEDIATE | | RAILS OR ORNAMENTAL PATTERNS SUCH THAT A | | 4-INCH DIAMETER SPHERE CANNOT PASS | | THROUGH ANY OPENING UP TO A HEIGHT OF | | 34". A BOTTOM RAIL OR CURB SHALL BE PRO- | | VIDED THAT WILL REJECT THE PASSAGE OF A | | 2" DIAMETER SPHERE. | | | | 2)1804.1.3 THE BOTTOM OF THE FOUNDA- | | TION SHALL EXTEND NO LESS THAN 12" | | BELOW FINISH GRADE. | | | | 3)2304.3.4 WOOD JOIST SHALL HAVE 18" | | CLEARENCE FROM THE BOTTOM OF JOIST TO | | EARTH OR ELSE BE PRESSURE TREATED WOOD | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561)659-8096 X8412 |
|