Date |
Text |
2002-12-21 00:00:00 | DENIED |
| REFERENCE: FBC-2001 424.2 SWIMMING POOLS |
| |
| A) PLEASE ADJUST YOUR NOTES, DETAILS, OR |
| SUBMITTALS TO REFLECT THE FOLLOWING IN- |
| FORMATION REQUIRED FOR PLAN REVIEW |
| 1) COMPLY WITH FBC-2001 SEC 424.2 |
| PRIVATE SWIMMING POOLS. (ADD TO NOTES) |
| 2) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP- |
| MENT AVOIDANCE. (DETAIL) THIS DETAIL NOT |
| CLEAR (SECTION 104.2.1 FBC CHAPTER 1) |
| 3) FBC-2001424.2.6.6.5 WHERE PROVIDED, |
| THE VACUUM OR PRESSURE CLEANER FITTING |
| SHALL BE LOCATED AT LEAST 6" AND NOT |
| GREATER THAN 12" BELOW THE MINIMUM OPER- |
| ATING WATER LEVEL OR AS AN ATTACHMENT TO |
| THE SKIMMER. (DETAIL) THIS DETAIL IS NOT |
| CLEAR (SECTION 104.2.1 FBC CHAPTER 1) |
| 4) FBC-2001 424.2.14.1 SWIMMING POOL |
| WATER HEATERS SHALL BEAR THE LABEL OF A |
| RECOGNIZED TESTING AGENCY. MANUFACTURE |
| SHEETS REQUIRED. (SUBMITTAL) |
| 5) FBC-2001 424.2.14.2 WATER RETENTION, |
| PROVIDE A POSITIVE MEANS OF RETAINING |
| WATER IN THE HEATER WHEN PUMP IS SHUT |
| OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) |
| 19) FBC-2001 104.2 BUILDING DRAWINGS, & |
| SPECIFICATIONS. TOO MANY SWIMMING POOL |
| PIPING SCHEMATICS ON THE PLANS. THIS IS |
| VERY CONFUSING. SHOW INDIVIDUAL PIPING |
| SCHEMATIC FOR POOL BEING BUILT,W/SPA. |
| SHOW PIPING FOR THE ENTIRE SYSTEM, PIPE |
| SIZES, VENTS, SUCTION AND DISCHARGE PIP- |
| ING EXT. DELETE ALL OTHER SCHEMATICS. |
| |
| REVIEW BY KEN STEVENS |
| (561) 659-8096 EXT 8377 |