Plan Review Notes
Plan Review Notes For Permit 02120137
Permit Number 02120137
Review Stop ENG
Sequence Number 2
Notes
Date Text
2003-05-13 00:00:00PASSED WITH PROVISOS:
 1. SUBJECT TO THE CONDITIONS;
 A. NO CONSTRUCTION, TEMPORARY OR
 PERMANENT IN 10.0' DRAINAGE AREA, ANY
 CONSTRUCTION, TEMPORARY OR PERMANENT IN
 THE SAID AREA SHALL BE REMOVED AT THE
 OWNER'S EXPENSE AT THE TIME OF REPLACING
 THE DRAINAGE SYSTEM BY THE CITY.
 B. PROPOSED AUGER CAST-IN-PLACE PILE
 TIPS AT SOUTHSIDE SUPPORTING THE
 STRUCTURE MUST BE LOCATED AT MINIMUM
 22.0' BELOW THE FINISHED GROUND.
  
 IF ANY QUESTIONS PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved