Plan Review Notes For Permit 02111908 |
Permit Number |
02111908 |
|
Review Stop |
B |
Sequence Number |
12 |
|
Notes |
Date |
Text |
2003-09-16 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02111908 | | ADD: 1865 OKEECHOBEE ROAD | | CONT: GLOBAL/ CONTACT: JERRY | | TEL: (561)436-1146 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | REVISION# 4 ROOF SCUPPERS | | | | 1503.4.2 OVERFLOW DRAINS AND SCUPPERS. | | WHERE THE CODE CALLS REQUIRES THE USE OF | | ROOF DRAINS AND OVERFLOW EMERGENCY | | SCUPPERS THE ROOF IS TO SLOPE TO THE | | ROOF DRAIN, THE OVERFLOW SCUPPER IS A | | SECONDARY MEANS OF DRAINAGE. THIS OVER- | | FLOW IS TO BE VISIBLE TO NOTIFY THE | | OWNERS OF A BLOCKAGE ON THE ROOF. THE | | CONCEPT SUBMITTED DOES NOT NOTIFY THE | | OWNERS OF ANY ROOF BLOCKAGE. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|