2003-04-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT 1.0 KITCHEN SINK SHALL COMPLY
 WITH 11-4.24 AND ALL SUBSECTIONS. PLEASE
 PROVIDE DETAILS.
 2) SHT 3.1 CLEANOUTS SHALL BE INSTALLED
 AT EACH CHANGE OF DIRECTION OF THE BLDG
 DRAIN OR HORIZONTAL WASTE OR SOIL LINES
 GREATER THAN 45 DEGREES. SEC. 708.3.3
 3) SHT 3.1 A SECOND DRINKING FOUNTAIN IS
 REQUIRED PER TABLE 403.1. THE HIGH/LOW
 IS CONSIDERED A SINGLE FIXTURE. ALSO SEE
 SECTION 410.1
  