Plan Review Notes For Permit 02110853 |
Permit Number |
02110853 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-12-17 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 2-FLOOD ZONE A8: WILL NEED THE ELEVATION | | CERTIFICATE. | | 3-SPECIFY SIZE OF ANCHOR BOLT AND WASHER | | FOR GARAGE DOOR STRUCTURAL BUCK DETAIL | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | 4-CLARIFY HOW DOES THE 34SH WINDOWS | | PROVIDE THE 24" MIN. CLEAR HEIGHT. | | ALSO, DOES THE 24+5 SH WINDOW PROVIDE | | 5.7 S.F. MIN. CLEAR OPENING? CLARIFY. | | SEE SEC. 1005.4.4 FBC 2001. | | 5-DETAIL S21 DOESN'T WORK AT CONNECTION | | OF COLUMN P1 LOCATED BETWEEN GARAGE | | AND STAIRWAY. REVISE AS REQ'D. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 6-REVISE CONNECTOR TC-1 SPECIFIED ON | | ROOF FRAMING PLAN AT FRONT ELEVATION. | | NEED WOOD TO WOOD CONNECTORS. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
|