Plan Review Notes For Permit 02110130 |
Permit Number |
02110130 |
|
Review Stop |
R |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2002-12-23 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 11/25/02: | | | | 2) FBC* 104.2.2SOME OF THE | | ARCHITECTURAL SHEETS ARE STILL NOT | | PROPERLY SEALED, FLORIDA STATUTES | | 61G1-16.001 THRU 16.003. | | | | 3) SHEET A-05.REMOVAL OF COLUMN | | BETWEEN THE LIVING ROOM AND MASTER | | BEDROOM WIC.THIS COLUMN WAS SUPPORTING | | GIRDER TRUSS SG2 AND WAS SUBJECT TO AN | | UPLIFT OF 4911 LBS (SEE 'FLORIDA QUALITY | | TRUSS' DESIGN).THE PROPOSED REVISION | | OMITS THE COLUMN AND RELOCATES THE | | GIRDER TRUSS WITHOUT HIGHLIGHTING THE | | NEW SUPPORT POINTS AND STATING THE | | RESPECTIVE UPLIFTS.SHEET A-05 SHALL BE | | REVISED TO CLEARLY SHOW THE LOCATION AND | | MAGNITUDE OF THE UPLIFT FORCES. |
|