Plan Review Notes
Plan Review Notes For Permit 02110130
Permit Number 02110130
Review Stop R
Sequence Number 1
Notes
Date Text
2002-11-25 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) THE SURVEY DRAWING SHALL SHOW AN
 EASEMENT ON LOT 44 FOR MEANS OF EGRESS
 FROM BEDROOM 2 TO THE STREET, VIA THE
 ATRIUM.
  
 2) FBC* 104.2.2THE ARCHITECTURAL
 SHEETS ARE NOT PROPERLY SEALED, FLORIDA
 STATUTES 61G1-16.001 THRU 16,003.
  
 3) SHEET A-05.REMOVAL OF THE COLUMN
 BETWEEN THE LIVING ROOM AND MASTER
 BEDROOM WIC WILL RESULT IN INCREASED
 LOADS AT THE REMAINING TRUSS SUPPORT
 POINTS.THE UPLIFTS ON THE ROOF FRAMING
 PLAN HAVE NOT BEEN REVISED TO REFLECT
 THE INCREASE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499