Plan Review Notes For Permit 02101988 |
Permit Number |
02101988 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-11-26 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-ARCHITECT TO REVISE DETAIL FOR ONE HR | | FIRE RATED WALL ASSEMBLY AT ZERO LOT | | LINE. TABLE REFERENCED ON DETAIL 11/S3 | | IS FOR CONCRETE WALL ASSEMBLIES, NOT | | FOR WOOD. SEE SECTION 709.6 FOR WOOD | | ASSEMBLIES AND PROVIDE COMPLETE | | ASSEMBLY DETAIL TAKING INTO CONSIDERA- | | TION INTERIOR AND EXTERIOR EXPOSURE TO | | THE FIRE AS REQUIRED BY TABLE 600 FBC. | | 2-ARCHITECT TO REVISE THE DIAPHRAGM | | SCHEDULE TO MATCH ENGINEERING SPECS. | | 3-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 4-PROVIDE COMPLETE INFORMATION ON DETAIL | | 41/S1. SPECIFY ANCHOR SIZE TO BE USED. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
|