2003-09-29 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 NO BUILDING PLAN REVIEW CARRIED OUT AT
 REV. #5.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 8/12/03:
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 10) FBC TABLE 1606.2ASHEET R1, TRUSS
 CONNECTORS/ANCHORS:
 A) "MSTA 60 HURRICANE CLIPS".MSTA 60
 AND MSTA TAPL 16 ARE NOT VALID USP
 REFERENCES.ASSUMING THE INTENDED
 ANCHOR IS USP TAPL 16, THE SPECIFIED
 FASTENERS DO NOT CORRELATE WITH THE USP
 CATALOGUE AND HAVE INSUFFICIENT CAPACITY
 FOR THE UPLIFT AT THE LOCATION CALLED UP
 ON THE PLAN (DERIVED FROM
 FBC TABLE 1606.2A, ASSUMING 10 PSF DL
 FOR WIND ANALYSIS). ALSO, AMEND THE ROOF
 PLAN TO STATE THE CALCULATED UPLIFT FOR
 EACH TRUSS.DELETE OR CORRECT THE
 REFERENCE TO DADE COUNTY APPROVAL NO.
 92-0604.03
 B) "USP TRUSS ANCHOR".TAPL 16 & TA 16
 DATA IN THE 2003 USP CATALOGUE DOES NOT
 CORRELATE WITH THE 1735 LB UPLIFT OR THE
 FASTENERS STATED ON THE PLANS.AMEND
 THE PLAN TO STATE ONE TYPE OF ANCHOR AND
 STATE THE CORRECT FASTENERS AND UPLIFT
 CAPACITY.
 C) "USP ANCHOR DETAIL". THE PLAN REFERS
 TO BOTH USP TAPL 16 AND (2) USP TA 16.
 NEITHER ONE, WHEN CHECKED IN THE USP
 CATALOGUE, CORRELATES WITH THE UPLIFT
 (5386 LBS) AND THE FASTENERS STATED ON
 THE PLANS.AMEND THE PLANS TO STATE THE
 CORECT REFERENCES, FASTENERS & UPLIFT
 CAPACITY.ALSO, THE DETAIL STILL REFERS
 TO HUGHES SHA-8 STRAP.AMEND THE DETAIL
 D) "USP ANCHOR DETAIL". THE PLAN REFERS
 TO BOTH USP TAPL 16 AND USP TA 16.THE
 SPECIFIED FASTENERS DO NOT CORRESPOND TO
 THE FASTENERS IN THE USP CATALOGUE.
 AMEND THE PLAN.
 E) "USP USC GIRDER TRUSS ANCHOR".
 AMEND THE PLAN TO SHOW WHICH USC ANCHOR
 IS TO BE USED AND TO SHOW THE
 APPROPRIATE FASTENERS.
  
 12) FBC 11-4.8.2ANNOTATE EACH OF THE
 NEW RAMPS ON THE PLANS TO VERIFY THAT
 THE SLOPE WILL NOT EXCEED 1 IN 12.
  
 26) FBC 13-103.0THE SUBMITTED ENERGY
 CODE COMPLIANCE FORM SHALL HAVE THE
 PROJECT ZIP, OWNER'S NAME AND PERMIT
 NUMBER (02101739) ADDED SHEET 1.ALSO,
 SHEET 2 MUST BE DATED BY THE PREPARER,
 SIGNED AND DATED BY THE BUILDING OWNER/
 OWNER'S AGENT, AND CERTIFIED FOR CODE
 COMPLIANCE BY THE DESIGN PROFESSIONALS
 RESPONSIBLE FOR THE ARCHITECTURAL,
 MECHANICAL, PLUMBING, ELECTRICAL AND
 LIGHTING SYSTEMS.
  
 32) THIS COMMENT HAS NOT BEEN ADDRESSED
 FBC 1606.1.7THE PLANS DO NOT STATE THE
 DESIGN WIND PRESSURE ON THE ROOF FOR
 SELECTION OF AN APPROPRIATE ROOF SYSTEM.
 ANNOTATE THE PLANS.
  
 34)713.13(2) FL. STATUTES.THE
 DESCRIBED WORKS DID NOT COMMENCE WITHIN
 90 DAYS OF RECORDING THE NOTICE OF
 COMMENCEMENT SO THE NOTICE IS VOID AND
 OF NO FURTHER EFFECT.IT SHALL BE RE-
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.
  
 35) THE PLANS SHALL BE RE-ROUTED TO
 HISTORIC PRESERVATION DIVISION BEFORE A
 PERMIT CAN BE ISSUED.
  
 36) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO