Date |
Text |
2002-11-26 00:00:00 | PLEASE PROVIDE A RECENT SIGNED SEALED |
| AND DATED PROPERTY SURVEY. |
| |
| PROVIDE CONSTRUCTION DETAILS FOR THE |
| MEZZANINE/SECOND FLOOR.IF THE DESIGN |
| IS TO BE DELEGATED SEE THE |
| RESONSIBILITY RULES FOR ENGINEERS AS TO |
| THE INFORMATION REQIRED ON THE PLANS. |
| |
| A DEMONSTRATION FOR THE REQUIREMENTS OF |
| FBC 1803.2 REGARDING THE FOUNDATIONS TO |
| BE CONSTRUCTED ADJACENT TO THE PROPERTY |
| LINE BEING ADDRESSED IS NECESSARY WHERE |
| APPLICABLE. |
| |
| THE EGRESS DOOR AT THE NORTH EAST |
| CORNEROF THE BUILDING APPEARS THAT IT |
| WILL BE OBSTRUCTED BY THE PARKING |
| SPACES.SEE FBC 1010.1. |
| |
| IF TEST AND OR NOTICE OF ACCEPTANCE |
| REPORTS FOR THE DOORS, WINDOWS, AND |
| ROOF COVERING ARE NOT INCLUDED WITH |
| THIS PERMIT AND PLANS, A SEPARATE |
| PERMIT, PLANS AND FEES WILL BE REQUIRED |
| FOR THAT WORK. |
| |
| SHOW THE STRUCTURAL DESIGN INFORMATION |
| IN ACCORDANCE WITH FBC 1606.1.7. |
| |
| ALSO, SHOW THE SOIL DESIGN PRESSURE |
| ASSUMED.NOTE WHAT METHOD OF WIND |
| DESIGN WAS USED.FBC 1606.2,ASCE |
| 7-98 SIMPLIFIED OR ANALYTICAL.SEE FBC |
| 1609.4.3 FOR REDUCTIONS AND LOAD |
| COMBINATIONS PERMITTED. |
| |
| SECTION KS1 ON S4 SHOWS A HORIZONTAL |
| PROJECTION OF INDETERMINATE LENGTH AND |
| THE ARCHITECTURAL PLANS INDICATE A |
| CANVAS CANOPY ON A4.PLEASE CLARIFY. |
| |
| PROVIDE CALCULATIONS FOR THE ROOF |
| DRAINAGE TO DEMONSTRATE COMPLIANCE WITH |
| FBC 1511.6.4 |
| |
| FOR PROJECTS OF THIS SCOPE A RESIDENT |
| INSPECTOR IS REQUIRED.CONTACT DON |
| NEELY AT 561-659-8096 X 8333 FOR MORE |
| INFORMATION. |
| |
| BEFORE A PERMIT TO CONSTRUCT MAY BE |
| ISSUED IMPACT FEES MUST BE PAID TO THE |
| COUNTY, THE PERMIT PLANS STAMPED BY |
| THAT OFFICE AND A COPY OF THE PAID |
| RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. CALL 561-233-5025 FOR MORE |
| INFORMATION. |
| |
| THE NOTICE OF COMMENCEMENT IS FOR LAND |
| CLEARING, PLEASE PROVIDE A NOC FOR THE |
| SCOPE OF WORK PROPOSED IN THIS PERMIT. |
| |
| PROVIDE A DESCRIPTION OF THE TYPE OF |
| WORK THAT IS PROPOSED TO TAKE PLACE IN |
| THIS BUILDING AND THE NATURE, |
| CHARACTERISTICS AND REPRESENTATIVE |
| QUANTITIES OF MATERIALS TO BE USED SO |
| THAT COMPLIANCE WITH FBC 308 MAY BE |
| DETERMINED. |