 BUILDING PLAN REVIEW
 PERMIT: 02100754
 ADD: 431 EL VEDADO ST
 CONT: O/B JERRELL, JAMES
 TEL: (561)659-1403
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)104.3.1.1.COUNTY AMENDMENTS:
 PLAN REVIEW MINIMUM REQUIREMENTS FOR
 PLAN REVIEW, 1 & 2 FAMILY BUILDINGS.
 1) SITE REQUIREMENTS,SET BACK SEPERA-
 TION (ASSUMED PROPERTY LINE)
 2) FIRE RESISTANT CONSTRUCTION
 (IF REQUIRED)
 3) FIRE
 4)SMOKE DETECTOR LOCATION
 5) EGRESS, EGRESS WINDOW SIZE AND
 LOCATION, STAIR CONSTRUCTION
 REQUIREMENTS
 6) STRUCTURAL REQUIREMENTS SHALL
 INCLUDE:
 FLOOR PLAN, WALL SECTIONS FROM THE
 FOUNDATION THROUGH THE ROOF, INCLUD-
 ING ASSEMBLY (PRODUCT APPROVALS) &
 MATERIALS, CONNECTOR TABLES, WIND
 REQUIREMENTS, STRUCTURAL CALCULA-
 TIONS (IF REQUIRED)
  
 3)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 4)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 5)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 6)1606.1.1 EXC (4) AF&PA WOOD FRAME
 CONSTRUCTION MANUAL FOR ONE & TWO
 FAMILY - 1995 SBC HIGH WIND EDITION
 1996 SHALL BE PERMITTED FOR APPLICABLE
 WOOD FRAME BUILDINGS OF GROUP 3 OCCU-
 PANCY FOR A BABIC WIND SPEED OF 146 MPH
 OR LESS IN EXPOSURE B AND 124MPH OR LESS
 IN EXPOSURE C IN ACCORDANCE WITH FIGURE
 1606 AND SECTION 1606.1.8.
  
 7)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 8) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) EXTERIOR SWING DOORS
 B) WINDOWS
 C) STORM SHUTTERS
 D) ROOF SHINGLES
  
 9) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 10)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 11) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 12)1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.
  
 13) 2303.03 MOISTURE PROTECTION, APPLY
 A VAPOR BARRIER,AFTER COMPACTION OF
 SOILS AND TERMITE TREATMENT.
  
 14) 2304.1.2 TERMITE TREAT SOILS BEFORE
 PLACEMENT OF CONCRETE.
  
 15) 2304.2.5 CLEARENCE BETWEEN WOOD
 SHEATHING AND EARTH, 6" UNLESS WOOD
 SHEATHING IS PRESSURE TREATED.
  
 16) UNDERLAYMENT APPLICATION, FOR ROOF
 SLOPES 2:12 UP TO 4:12, SEE SECTIONS
 1&2.
  
 17) PROVIDE HOLDDOWN INFORMATION, THE
 MANUFACTURER, MODEL FOR STUDS, TOP
 AND BOTTOM PLATES, MAGNITUDE OF FORCES
 BEING RESISTED, INCLUDING UPLIFT, GRAV-
 ITY & LATERAL LOADS. PLAN INDICATES THE
 USE OF RED HEAD BRAND ANCHORS, 3/8"
 BY 5" WHAT TYPE OF FASTENER, WEDGE, DROP
 INSLEEVE-ALL, OR MACHINE SCREW ANCHOR?
 IS THE 5" A WORKING LENGHT? SINCE THE
 ANCHOR SHALL BE WITHIN 2" OF THE EDGE
 HAS A DERATING FACTOR BEEN TAKEN?
 THE PLANS DO NOT GIVE THE ATTACHMENT OF
 THE TRUSSES TO THE EXISTING STRUCTURE
 NOR THE ADDITION.HEADER SIZES?
  
 THESE PLANS ARE INCOMPLETE AND ARE
 CONCEPTUAL IN NATURE. A COMPLETE REVIEW
 CAN NOT BE COMPLETED AT THIS TIME.
 FUTURE REVIEWS MAY INCLUDE DIFFERENT
 OR NEW COMMENTS.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW