Date |
Text |
2002-10-12 00:00:00 | DENIED |
| REFERENCE: FBC-2001 CHAPTER 11 |
| FBC-2001 PLUMBING |
| FBC-2001 |
| |
| 1) SHT CIVIL 6 0F 9 OIL/WATER SEPARATOR |
| DETAIL, 2 WAY CLEAN OUTS ARE REQUIRED. |
| 2) FOR OIL/WATER SEPARATOR SIZE CONTACT |
| RODNEY COMPO, ENVIRONMENTAL COMPLIANCE |
| MANAGER, (561) 837-4074. WASTE ORD. # |
| 2938-96 |
| 3) SHT LP-1 SEPARATE IRRIGATION PERMIT |
| IS REQUIRED. |
| 4) SHT A-1 MINIMUM FACILITIES CALLS FOR |
| 3 DRINKING FOUNTAINS. 2 HI/LOW DRINKING |
| FOUNTAINS ARE SHOWN WHICH COUNT AS 2. |
| SEE SECTION 410.1 A WATER COOLER CAN BE |
| USED AS A THIRD DRINKING FOUNTAIN. IF |
| USED IT SHALL COMPLY WITH ARI-1010. |
| PLEASE PROVIDE MANUFACTURE CUT SHEETS. |
| 5) SHT A-1.3 DETAIL #7 LIFT PLATFORM PIT |
| SHOWS A DRAIN, BUT NO PIPING IS INDICAT- |
| ED OR SHOWN. PLEASE CLAIRFY. |
| 6) SHT A-2 PLEASE PROVIDE CALCULATIONS |
| FOR PRIMARY AND SECONDARY ROOF DRAINS. |
| SHOW TOTAL SQUARE FOOTAGE OF ROOF AREA |
| INCLUDING 1/2 AREA OF ALL VERTICAL WALLS |
| SHOW SQUARE FOOTAGE FOR EACH ROOF DRAIN. |
| SHOW LOCATION AND SIZE FOR SECONDARY |
| ROOF DRAINS. |
| 7) SHT A-8 FINISH SCHEDULE. THE WALLS OF |
| ALL PUBLIC RESTROOMS SHALL BE LINED WITH |
| A NON ABSORBENT MATERIAL TO A HEIGHT OF |
| 4 FEET. SEC 1204.2 - PLEASE INDICATE THE |
| PAINT TYPE FOR WALLS. |
| 8) SHT A-9 DETAIL #7 WATER CLOSET SHALL |
| BE SET 1'6" OFF WALL TO CENTER, NOT 1'4" |
| AS SHOWN. LAV SHALL BE SET 34" TO FLOOD |
| RIM LEVEL. |
| 9) SHT A-9 DETAIL #14 W/C TO BE SET 1'6" |
| TO CENTER OFF WALL NOT 1'4" AS SHOWN. |
| 10) SHT A-10 DETAIL #16 SHOW DETAIL FOR |
| BENCH PER 11-4.35.4 |
| 11) SHT M-4 PLUMBING NOTES: NUMBERING |
| SECQUENCE NOT CONSISTANT. #'S 10-11-12 |
| REPETE. SECOND #10 REFERS TO AIR CHAMB- |
| ERS WHICH ARE NOT APPROVED. PLEASE DE- |
| LETE REFERENCE AND RE-NUMBER NOTES. |
| 12) SHT M-4 RELIEF (T/P) VALVE DISCHARGE |
| SHALL NOT BE TRAPPED. SEC 504.7.1 |
| WATER HEATER REQUIRES THERMAL EXPANSION |
| CONTROL. SEC 607.3.2. PLEASE SHOW ON DE- |
| TAIL. |
| |
| REVIEW BY KEN STEVENS |
| (561) 659-8096 EXT 8377 |