2003-04-14 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 02090718 |
| ADD: 1222 OMAR RD |
| CONT: ROBERT TURSO |
| TEL: (561)439-7326 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| REVISION: DENIED |
| |
| 1) EXTERIOR STAIRS SECTION 1006.2.4 |
| EXTERIOR STAIRS SHALL BE SEPERATED FROM |
| THE INTERIOR OF THE BUILDING BY WALLS |
| WITH A FIRE RESISTANCE RATING OF NOT |
| LESS THAN 1 HR. WITH FIXED OR SELF CLOS- |
| ING OPENING PROTECTIVES AS REQUIRED FOR |
| ENTERIOR STAIRS.SEE ATACHMENT. |
| |
| THE APPROVED PLAN INDICATED 3 WINDOWS |
| ON THE FIRST FLOOR, NO REFRENCE TO THESE |
| WINDOWS BEING DELETED? 1 HR RATING. |
| |
| THE DOORS DIRECTLY UNDER THE STAIRS |
| WILL ALSO NEED TO BE RATED 1 HR. |
| |
| LOOK FOR COMMENTS BY THE OTHER PLAN |
| REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| ON THE APPLICATION, PLANS, OR ATTACHED |
| SEPARATELY. WHEN RESUBMITTING PLANS |
| PLEASE CLEARLY INDICATE THE REVISION AND |
| REMOVE AND REPLACE ANY PAGES AS NECESS- |
| ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| THE PLANS WHEN RESUBMITTING PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN |
| BE FOUND, WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| JIM WITMER |
| BUILDING PLAN REVIEW |