2003-04-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02090718
 ADD: 1222 OMAR RD
 CONT: ROBERT TURSO
 TEL: (561)439-7326
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 REVISION: DENIED
  
 1) EXTERIOR STAIRS SECTION 1006.2.4
 EXTERIOR STAIRS SHALL BE SEPERATED FROM
 THE INTERIOR OF THE BUILDING BY WALLS
 WITH A FIRE RESISTANCE RATING OF NOT
 LESS THAN 1 HR. WITH FIXED OR SELF CLOS-
 ING OPENING PROTECTIVES AS REQUIRED FOR
 ENTERIOR STAIRS.SEE ATACHMENT.
  
 THE APPROVED PLAN INDICATED 3 WINDOWS
 ON THE FIRST FLOOR, NO REFRENCE TO THESE
 WINDOWS BEING DELETED? 1 HR RATING.
  
 THE DOORS DIRECTLY UNDER THE STAIRS
 WILL ALSO NEED TO BE RATED 1 HR.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026