Plan Review Notes For Permit 02090646 |
Permit Number |
02090646 |
|
Review Stop |
P |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2003-04-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | CODE REQUIREMENTS. | | FROM PREVIOUS REVIEW: SHT 2 0F 3 UNIT #5 | | LAV AND KITCHEN SINK SHALL NOT BE ON THE | | SAME RISER, (DIFFERENT WALLS). | | FROM PREVIOUS REVIEW: 2ND FLOOR UNIT #6 | | SHALL TIE IN DOWNSTREAM OF BATHROOM FOR | | UNIT #5 | | KITCHEN MOVED TO BATHROOM GROUP IN BATH | | #1 SHALL NOT DRAIN INTO THE WET VENTED | | BATHROOM GROUP PER SECTION 909.1 | | BATH #5 HAS A HORIZONTAL DRY VENT. THIS | | IS NOT APPROVED PER SECTION 905.3 | | KITCHEN SINK IN UNIT #6 SHALL NOT DRAIN | | INTO THE BATHROOM GROUP. SECTION 909.1 | | KITCHEN SINK IN UNIT #2 SHALL NOT DRAIN | | INTO THE BATHROOM GROUP. SECTION 909.1 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|