Date |
Text |
2002-10-09 00:00:00 | DENIED |
| REFERENCE: FBC-2001 424.2 SWIMMING POOLS |
| |
| A) PLEASE ADJUST YOUR NOTES, DETAILS, OR |
| SUBMITTALS TO REFLECT THE FOLLOWING IN- |
| FORMATION REQUIRED FOR PLAN REVIEW |
| 1) FBC-2001424.2.7.1 POOL CIRCULATING |
| PUMPS SHALL BE EQUIPPED ON THE INLET |
| SIDE WITH AN APPROVED TYPE HAIR AND LINT |
| STRAINER WHEN USED WITH A PRESSURE FIL- |
| TER. (DETAIL) |
| 2) FBC-2001 424.2.8.1 VALVES SHALL BE |
| MADE OF MATERIALS THAT ARE APPROVED IN |
| THE FLA BLDG CODE, PLUMBING. THEY WILL |
| BE READILY ACCESSIBLE FOR MAINT. AND RE- |
| MOVAL. SEC 424.2.8.2 FULL WAY VALVES |
| SHALL BE INSTALLED TO INSURE PROPER FUN- |
| CTION OF THE FILTRATION AND PIPING SYS- |
| TEM. SEC 424.2.8.3 WHERE CHECK VALVES |
| ARE INSTALLED THEY SHALL BE OF THE SWING |
| OR VERTICAL CHECK PATTERNS. SEC 424.2.8. |
| 4 COMBINATION VALVES SHALL REQUIRE APP- |
| ROVAL OF THE ADMINISTRATIVE AUTHORITY |
| PRIOR TO THEIR INSTALLATION. VALVE MISS- |
| ING FOR (1) MAIN DRAIN LINE. |
| 3) FBC-2001 424.2.13.2JOINTS AND CON- |
| NECTIONS, FBC PLMG SEC 605.21, PURPLE |
| PRIMER REQUIRED ON PVC PIPING. (ADD TO |
| NOTES) |
| |
| REVIEW BY KEN STEVENS |
| (561) 659-8096 EXT 8377 |