Plan Review Notes For Permit 02081103 |
Permit Number |
02081103 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-08-26 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) FBC 1015.4GUARDRAIL.FOR THE 1/4" | | ALUMINUM PLATE, SHOWN ON THE ELEVATIONS | | AND SHEET S-3 SECTION 1, PROVIDE DETAILS | | OF THE METHOD OF ATTACHMENT TO THE | | SUPPORTING STRUCTURE.SEE NOTE BELOW. | | | | 2) FBC 1015.4 STAIR GUARDRAIL, SHEET S-4 | | SECTION 2.PROVIDE DETAILS TO SHOW | | ATTACHMENT OF THE ALUMINUM HANDRAIL | | SYSTEM TO THE STAIR STRINGER.SEE NOTE | | BELOW. | | | | 3) TOWER BASE PLATE BOLTS.SHEET S-4, | | DETAIL D SHOWS ONLY 2 ANCHORS PER BASE. | | AMEND THE DETAIL TO CORRELATE WITH THE | | NORTH AND EAST ELEVATIONS, WHICH SHOW | | 4 ANCHORS. | | | | NOTE: | | THE DETAILS SHALL CONSIDER GALVANIC | | CORROSION. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|