 BUILDING PLAN REVIEW
 PERMIT: 02080925
 ADD:*****LIBERTY BAY*****
 ****MODEL"E"****
 CONT: HOME DYNAMICS CONSTRUCTION
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SHEET A-2, NOTE: MONOLITHIC CONCRETE
 FOUNDATION WITHOUT HOOKBAR DESIGN BY
 RATIONAL ANALYSIS, WHAT IS THE MINIMUM
 LENGHT DOWEL ALLOWABLE, EMBEDDMENT DEPTH
  
 2) SHEAR WALLS WHERE THE STRUCTURE
 DEPENDS ON MASONARY WALLS FOR LATERAL
 STABILITY, SHEAR WALLS SHALL BE PROVIDED
 INDICATE COMPLIANCE, TRANSITION FROM
 2ND STORY FRAME WALLS, WIND 90 DEGREES
 TO THE FRONT OF THE STRUCTURE, FRONT
 ENTRY AREA? INDICATE HOW FLOOR ACTS AS
 A DIAPHRAM, TO TIE IN 1ST TO 2ND FLOOR
 FRAMING? TABLE 2310.2B
  
 3) SHEET A-3 INDICATES 130 MPH, WE ARE
 LOCATED IN A 140 MPH WIND ZONE. ALSO
 DESIGN LOADS, WIND LOADS AS PER CHAP 16
 NOT 6, AND ASCE 7-98.
  
 4) SHEET A-4 MEAN ROOF HEIGHT < 25'
 ROOF SHEATHING NAILING REQUIREMENTS
 ZONES 1 & 28D COMMONS
 6" EDGES & 6" INTERMEDIATES
 ZONE 38D COMMONS
 4"EDGES & 6" INTERMEDIATES
  
 5) PROVIDE KEY PLAN FOR INSTALLATION
 SCHEDULE/ STORM SHUTTERS
  
 6)1007.8.1 WINDERS SHALL HAVE A
 MINIMUM TREAD DEPTH OF 6" AT THE NARROW-
 EST EDGE & SHALL HAVE A MINIMUM TREAD
 DEPTH OF 11" AT A POINT 12" FROM THE
 NARROW EDGE. WINDERS SHALL BE PERMITTED
 TO BE USED AS A COMPONENT IN MEANS OF
 EGRESS WITHIN A DWELLING UNIT.
  