Plan Review Notes For Permit 02080203 |
Permit Number |
02080203 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-08-27 00:00:00 | ************BUILDING PROVISO************ | | | | 1) STRUCTURE IS LOCATED IN AN 'AO' FLOOD | | ZONE AN ELEVATION CERTIFICATE IS | | REQUIRED. | | | | 2) NO UPLIFT OR CONNECTORS ARE INDICATED | | ON THE ROOF FRAMING PLAN ON SHEET 3A. | | THE ANCHOR SCHEDULE SPECIFIES CONNECTORS | | TO BE USED UNLESS OTHERWISE NOTED ON THE | | FRAMING PLAN. IF THE REACTION VALUES | | GIVEN ON THE TRUSS DRAWINGS EXCEED THE | | CONNECTOR VALUES LISTED IN THE SCHEDULE, | | A REVISED ROOF FRAMING PLAN WILL BE | | REQUIRED. | | | | 3)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - ARCHED TOP FIXED GLASS WINDOW AS SHOWN | | ON REAR ELEVATION. | | - STORM PANELS(THE KEY PLAN AND INSTALL- | | ATION SCHEDULE DID NOT HAVE A PRODUCT | | APPROVAL WITH THEM) |
|