Plan Review Notes For Permit 02061589 |
Permit Number |
02061589 |
|
Review Stop |
R |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2002-08-19 00:00:00 | *****BUILDING PROVISO***** | | | | 1) FL BLD CODE 1804.2.2 QUESTIONABLE | | SOILS, WHERE THE BEARING CAPACITY IS | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | SOILS REPORT IS TO BE PART OF THE PLAN | | REVIEW. THIS PROVISO IS THAT SOILS | | REPORT BE SUBMITTED TO THIS OFFICE BE- | | FORE FOUNDATION INSPECTION FOR REVIEW. | | | | 2)1606.1.4(1) IN WIND BORNE DEBRIS | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | ASSUMED TO BE OPENINGS UNLESS SUCH | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | WITH AN IMPACT RESISTANT COVERING MEET- | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | LARGE MISSLE TEST. | | MISSING PRODUCT TESTING REPORT FOR GLASS | | BLOCK. | | FL BLD CODE 2405.2 HAZARDOUS LOCATION | | PROVIDE SAFETY GLASS FOR THIS LOCATION: | | MISSING INFORMATION ON THICKNESS OF | | GLASS BLOCK, MASTER BATH TUB & BATH# 2. | | JIM WITMER | | PLAN REVIEW |
|