Date |
Text |
2002-07-31 00:00:00 | |
| BUILDING PLAN REVIEW |
| PERMIT: 02061589 |
| ADD: 3568 TURTLE ISLAND COURT |
| CONT: M/I HOMES INC (BONA VISTAIII) |
| TEL: (561)471-3440 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| 1) FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORT, SBCCI OR DADE COUNTY |
| REPORT ARE ACCEPTED. |
| |
| 2)1503.4.4 PROTECTION AGAINST DECAY & |
| TERMITES. CONDENSATE LINES & ROOF DOWN |
| SPOUTS SHALL DISCHARGE AT LEAST 1 FT. |
| AWAY FROM THE STRUCTURE SIDEWALL, |
| WHETHER BY UNDERGROUND PIPING, TAIL EX- |
| TENSIONS, OR SPLASH BLOCKS. |
| |
| 3)1204.3 SHOWERS. SHOWER COMPARTMENTS |
| SHALL HAVE FLOORS AND WALLS CONSTRUCTED |
| OF SMOOTH, CORROSION RESISTANT AND NON- |
| ABSORBENT WATER-RESISTANT MATERIALS TO A |
| HEIGHT OF NOT LESS THAN 70" ABOVE THE |
| COMPARTMENT FLOOR AT DRAIN. |
| |
| 4)FIGURE 1606 WIND-BORNE DEBRIS |
| REGION; INDICATES THAT W.P.B. CITY OF IS |
| LOCATED IN THE 140 MPH ZONE. PLANS ARE |
| TO INDICATE THIS. |
| |
| 5)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| INFORMATION RELATED TO WIND SHALL BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| SHEET 7 OF 9 THE ABOVE VALUES ARE FOR |
| THE TOTAL BUILDING NOT JUST ROOF AS ON |
| PLANS. THE INTERNAL PRESSURE COEFFICIENT |
| IS 0.18. |
| |
| 6) FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORT, SBCCI OR DADE COUNTY |
| REPORT ARE ACCEPTED. |
| MISSING REPORT FOR GLASS BLOCK, THIN |
| WALL REQUIRES LARGE MISSLE PROTECTION, |
| THICK WALL MEETS IMPACT TESTING, SOLID |
| GLASS BLOCK MEETS LARGE MISSLE IMPACT |
| TESTING. SBCCI OR DADE COUNTY REPORT. |
| |
| 7)SITE SPECIFIC ENGINEERING (PRODUCT |
| APPROVAL) REQUIRES THE WET SIGNATURE, |
| DATE AND EMBOSSED SEAL OF THE ENGINEER |
| CERTIFYING THE PRODUCT AND SIGNATURE |
| AND SEAL OF THE DESIGN PROFESSIONAL |
| OF RECORD. MISSING SIGNATURE & SEAL OF |
| THE DESIGN PROFESSIONAL, MISSING SITE |
| ADDRESS. |
| |
| 8)FL BLD CODE 2001 SECTION 103.6, |
| 1606.1.4, 1707.4 & 3401.7.2.4. |
| PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| SCHEDULE SUMMARIZING & IDENTIFYING |
| OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| BAR REINFORCING REQUIREMENTS, WALL PRES- |
| SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| SUBMITTED AT TIME OF PERMIT APPLICATION |
| TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE. MISSING KEY PLAN THAT TIES |
| WITH SHUTTER SCHEDULE. REVIEWING THE |
| SITE SPECIFIC INFO, INDICATES, VARIES |
| SEE SHEET DEPTH OF FASTENER EXAMPLE: |
| 1 1/4 VARIES SEE SHEET NOTHING IS HIGH- |
| LIGHTED YOU COULD USE A 1 1/4 FASTENER |
| IN WOOD AND IT BE THE WRONG FASTENER!!! |
| SEE ATTACHED COPY FOR EXAMPLE. REMEMBER |
| THIS IS SITE SPECIFIC!!!! |
| INDICATE ON THE SECOND FLOOR IF THE |
| WINDOWS TO BE USED ARE INSTALLED ON |
| BUCKS OR IF FACE MOUNTED WITH FLANGE? |
| INDICATE IF FLANGED HOW THE WINDOWS ARE |
| TO MAINTAIN DISTANCE FROM GLAZING TO |
| SHUTTER? |
| 1707.4.4.1 ANCHOR REQUIREMENTS: |
| WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR |
| ED IN ACCORDANCE WITH THE PUBLISHED |
| MANUFACTURER'S RECOMMENDATIONS TO |
| ACHIEVE THEDESIGN PRESSURE SPECIFIED. |
| SUBSTITUTE ANCHORING SYSTEM USED FOR |
| THE SUBSTRATE NOT SPECIFIED BY THE |
| FENESTRATION MANUFACTURER SHALL PROVIDE |
| EQUAL OR GREATER ANCHORING AS DEMONSTRA- |
| TED BY ACCEPTED ENGINEERING PRACTICES. |
| THIS SAME IDEA HOLD TRUE FOR STORM |
| SHUTTERS, THE TABLES PROVIDED INDICATE |
| VALUES FOR CONCRETE, HOLLOW BLOCK, |
| AND WOOD. WHAT DERATING VALUE IS GIVEN |
| FOR FILLED CELL? OR ARE TAPCONS GOING TO |
| BE 2 1/2", SITE SPECIFIC 1 1/4" BUT |
| VARIES? |
| |
| 9) PROVIDE ENGINEERING FOR BUTT GLASS |
| ASSEMBLIES PER 1997 SBC 2406.2. |
| |
| |
| 10)FL BLD CODE 1804.2.2 QUESTIONABLE |
| SOILS, WHERE THE BEARING CAPACITY IS |
| NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| |
| 11) 2305.2.2 FLOOR/CEILING ASSEMBLIES |
| SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/ |
| ING ASSEMBLIES SEPERATING USEABLE SPACE |
| INTO 2 OR MORE APPROXIMATE AREAS WITH NO |
| AREA GREATER THAN 500 SQ FT. DRAFTSTOP- |
| PING SHALL BE PROVIDED PARALLEL TO THE |
| MAIN FRAMING MEMBERS. |
| |
| 12) SECOND FLOOR OVER GARAGE MISSING |
| INSULATION IN FLOOR SYSTEM. |
| |
| 13)FL BLD CODE 2309.6 ATTIC ACCESS, PRO- |
| VIDE ATTIC ACCESS 20"X36",ND FL. |
| |
| 14)FL BLD CODE 2405.2 HAZARDOUS LOCATION |
| PROVIDE SAFETY GLASS FOR THIS LOCATION: |
| MASTER BATH TUB/ SHOWER |
| BATH# 2 WINDOW |
| |
| 15)2504.2.2 INSTALLATION OF EXTERIOR |
| LATHING AND FRAMING SHALL COMPLY WITH |
| ASTM C-1063. |
| |
| 16) SHEET A & B WHAT CUT SECTIONS ARE |
| THESE TAKEN FROM? |
| |
| 17) SECTION 5/B 18"X 18" CORNER BARS VS |
| SHEET 6 25"X25" F# 5'S? |
| |
| 18) WALL SECTION 1-4 NO INFO TO TIE IN, |
| WALL SECTION NO INFO ON WALL STRAPPING? |
| |
| 19)SHEET 7 ROOF NOTES, NOTE# 7, NDI- |
| CATES ROOFING ZONE 3 SEE CITY AMENDMENTS |
| 23206.1, REVISE NOTE 7. |
| |
| 20) SHEET 2 FOUNDATION DETAIL FOR 2 |
| STORY SHOWER NO DIMENSION GIVEN, WHAT IS |
| DEPICTED ISN'T TO CODE. |
| |
| LOOK FOR COMMENTS BY THE OTHER PLAN |
| REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| ON THE APPLICATION, PLANS, OR ATTACHED |
| SEPARATELY. WHEN RESUBMITTING PLANS |
| PLEASE CLEARLY INDICATE THE REVISION AND |
| REMOVE AND REPLACE ANY PAGES AS NECESS- |
| ARY. A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| DESCRIPTION OF THE REVISION MADE, IDEN- |
| TIFYING THE SHEET OR SPECIFICATION PAGE |
| WHERE THE CHANGES CAN BE FOUND, WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU |
| FOR YOUR ANTICIPATED COOPERATION. |
| JIM WITMER |
| PLAN REVIEW |
| TEL: (561)659-8096 EX.8412 |
| FAX: (561)659-8026 |