 BUILDING PLAN REVIEW
 PERMIT: 02061589
 ADD: 3568 TURTLE ISLAND COURT
 CONT: M/I HOMES INC (BONA VISTAIII)
 TEL: (561)471-3440
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
  
 2)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 3)1204.3 SHOWERS. SHOWER COMPARTMENTS
 SHALL HAVE FLOORS AND WALLS CONSTRUCTED
 OF SMOOTH, CORROSION RESISTANT AND NON-
 ABSORBENT WATER-RESISTANT MATERIALS TO A
 HEIGHT OF NOT LESS THAN 70" ABOVE THE
 COMPARTMENT FLOOR AT DRAIN.
  
 4)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 5)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 SHEET 7 OF 9 THE ABOVE VALUES ARE FOR
 THE TOTAL BUILDING NOT JUST ROOF AS ON
 PLANS. THE INTERNAL PRESSURE COEFFICIENT
 IS 0.18.
  
 6) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 MISSING REPORT FOR GLASS BLOCK, THIN
 WALL REQUIRES LARGE MISSLE PROTECTION,
 THICK WALL MEETS IMPACT TESTING, SOLID
 GLASS BLOCK MEETS LARGE MISSLE IMPACT
 TESTING. SBCCI OR DADE COUNTY REPORT.
  
 7)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. MISSING SIGNATURE & SEAL OF
 THE DESIGN PROFESSIONAL, MISSING SITE
 ADDRESS.
  
 8)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE. MISSING KEY PLAN THAT TIES
 WITH SHUTTER SCHEDULE. REVIEWING THE
 SITE SPECIFIC INFO, INDICATES, VARIES
 SEE SHEET DEPTH OF FASTENER EXAMPLE:
 1 1/4 VARIES SEE SHEET NOTHING IS HIGH-
 LIGHTED YOU COULD USE A 1 1/4 FASTENER
 IN WOOD AND IT BE THE WRONG FASTENER!!!
 SEE ATTACHED COPY FOR EXAMPLE. REMEMBER
 THIS IS SITE SPECIFIC!!!!
 INDICATE ON THE SECOND FLOOR IF THE
 WINDOWS TO BE USED ARE INSTALLED ON
 BUCKS OR IF FACE MOUNTED WITH FLANGE?
 INDICATE IF FLANGED HOW THE WINDOWS ARE
 TO MAINTAIN DISTANCE FROM GLAZING TO
 SHUTTER?
 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
 THIS SAME IDEA HOLD TRUE FOR STORM
 SHUTTERS, THE TABLES PROVIDED INDICATE
 VALUES FOR CONCRETE, HOLLOW BLOCK,
 AND WOOD. WHAT DERATING VALUE IS GIVEN
 FOR FILLED CELL? OR ARE TAPCONS GOING TO
 BE 2 1/2", SITE SPECIFIC 1 1/4" BUT
 VARIES?
  
 9) PROVIDE ENGINEERING FOR BUTT GLASS
 ASSEMBLIES PER 1997 SBC 2406.2.
  
  
 10)FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
  
 11) 2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS.
  
 12) SECOND FLOOR OVER GARAGE MISSING
 INSULATION IN FLOOR SYSTEM.
  
 13)FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36",ND FL.
  
 14)FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 MASTER BATH TUB/ SHOWER
 BATH# 2 WINDOW
  
 15)2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063.
  
 16) SHEET A & B WHAT CUT SECTIONS ARE
 THESE TAKEN FROM?
  
 17) SECTION 5/B 18"X 18" CORNER BARS VS
 SHEET 6 25"X25" F# 5'S?
  
 18) WALL SECTION 1-4 NO INFO TO TIE IN,
 WALL SECTION NO INFO ON WALL STRAPPING?
  
 19)SHEET 7 ROOF NOTES, NOTE# 7, NDI-
 CATES ROOFING ZONE 3 SEE CITY AMENDMENTS
 23206.1, REVISE NOTE 7.
  
 20) SHEET 2 FOUNDATION DETAIL FOR 2
 STORY SHOWER NO DIMENSION GIVEN, WHAT IS
 DEPICTED ISN'T TO CODE.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.