Date |
Text |
2002-08-01 00:00:00 | CHECKLIST: |
| 1-PROVIDE SOIL TEST REPORT SIGNED AND |
| SEALED BY ENGINEER. |
| 2-PROVIDE UPDATED/CORRECTED SURVEY. |
| 3-PROVIDE DETAIL/SPECS FOR CEILING INS- |
| TALLATION AT ENTRY AND REAR PORCHES. |
| SEE ASTM C-1063 FOR MINIMUM FASTENERS |
| TO BE USED. |
| 4-PROVIDE ATTIC ACCESS AT MASTER BEDROOM |
| WING AND AT 2ND FLOOR. SEC 2309.6 FBC |
| 5-CLARIFY SIZE OF EGRESS WINDOWS AT 2ND |
| FLOOR. SH24 AND SH34 ARE TYP. 48" HIGH |
| AND THEY WILL NOT PROVIDE THE MIN. 24" |
| CLEAR HEIGHT REQUIRED BY SEC. 1005.4.4 |
| FBC 2001. ALSO, NEED 5.7SF MIN. CLEAR |
| OPENING (SH24 DOESN'T MAKE IT). ARE |
| THEY CUSTOM MADE WINDOWS FOR EGRESS? |
| 6-SPECIFY FIREBLOCKING MATERIAL AND |
| LOCATION AT STAIRS. SEC. 2305.1 FBC |
| 7-SPECIFY DRAFSTOPPING LOCATION AND |
| MATERIAL AT 2ND FLOOR FRAMING PLAN. |
| SEC. 2305.2.2 FBC 2001. |
| 8-PROVIDE 2X STRUCTURAL JAMB BUCK DETAIL |
| FOR SLIDING GLASS DOORS. SEE PRODUCT |
| APPROVAL AND PLANS-SHEET A-1. |
| 9-SPECIFY CEILING FAN SIZE AND LOCATION |
| (SEE ELEC. PLAN). THEY SHALL BE IN |
| PLACE FOR INSPECTION IF CREDIT FOR |
| THEM IS TAKEN IN THE ENERGY CALCS. |
| SEE TABLE 6-6 CHAPTER 13 FBC FOR SIZES |
| 10-LEFT ELEVATION DOESN'T MATCH FLOOR |
| PLAN. REVISE AS REAUIRED. |
| 11-PROVIDE DETAILS/SPECS FOR ALL TOP |
| CONNECTIONS OF STEEL AND WOOD COLS. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC |
| 12-REVISE DETAIL D/S-2. IT'S A WOOD COL. |
| NOT STEEL. |
| 13-SPECIFY UPLIFT CONNECTOR FOR ROOF |
| TRUSSES RESTING ON 2X LEDGER AT REAR |
| PORCH AREA. SEC. 104.2.1.2 CITY |
| AMENDMENTS TO FBC 2001. |
| 14-STORM SHUTTERS INFORMATION IS MISSING |
| KEY PLAN & COMPLETE INSTALLATION SCHED |
| SUBMIT COMPLETE INFORMATION UNDER A |
| SEPARATE PERMIT. |
| 15-PROVIDE PRODUCT APPROVAL FOR: |
| A)FIXED WINDOWS WITH ARCHED TOP AS SHOWN |
| ON ARCHITECTURAL PLANS. |
| B)GLASS BLOCK WITH SPECS FOR ONE HOUR |
| FIRE RATED ASSEMBLY REQUIRED BY TABLE |
| 600 FBC 2001. |
| C)ENTRY DOORS WITH LEGIBLE DRAWINGS. |
| |
| 16-ARCHITECT TO SEE PLANS FOR ADDITIONAL |
| COMMENTS AND UPDATE/REVISE AS REQUIRED. |