 BUILDING PLAN REVIEW
 PERMIT: 02061099
 ADD: 3729 VICTORIA RD
 CONT: M/I HOMES INC
 TEL: (561)471-3440
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
 SHEET 1 OF 7 FRONT ELEVATION VS LEFT
 ELE. FOR BEDROOM # 3 DETAIL WINDOW SILL
 AND ROOF FLASHING AND MAINTAIN 44" TO
 SILL?
  
 3)1204.3 SHOWERS. SHOWER COMPARTMENTS
 SHALL HAVE FLOORS AND WALLS CONSTRUCTED
 OF SMOOTH, CORROSION RESISTANT AND NON-
 ABSORBENT WATER-RESISTANT MATERIALS TO A
 HEIGHT OF NOT LESS THAN 70" ABOVE THE
 COMPARTMENT FLOOR AT DRAIN.
  
 4)1204.4 JOINTS. BUILT IN TUBS WITH
 SHOWERS SHALL HAVE WATER-PROOF JOINTS
 BETWEEN THE TUB & WATER RESISTANT WALL.
  
 5)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 6)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 7)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 SHEET 1 OF 7 LOADS ON ROOF, ABOVE
 ARE THE VALUES/ LOADS THE TOTAL BUILDING
 IS TO DESIGNED TO NOT JUST THE ROOF.
 THE INTERNAL PRESSURE COEFFICIENT
 SHOULD READ 0.18!
  
 8) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 FOR THIS JOB PRODUCT REPORT FOR
 ALUMINIUM HORIZONTAL ROLLING WINDOWS IS
 OK, EXPIRED AFTER APPLICATION DATE,
 REPLACE UNDER NEW PERMIT APPLICATION.
  
 9)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. THE DESIGN PROFESSIONAL OF
 RECORD FOR THIS PRODUCT HAS NOT SIGNED &
 SEALED THE RIGHT PORTION OF THIS AFFIDAV
 IT, NOR SUPPLIED A SIGNED & SEALED COVER
 SHEET APPROVING THIS APPLICATION IN
 THIS SPECIFIC UNIT, (NO ADDRESS).
 THE ENGENEERING SHEETS ARE NOT HIGH-
 LIGHTED SHOWING WHAT DETAILS ARE BEING
 USED, WHAT TYPE OF ANCHOR BEING USED?
 THERE IS NO KEY PLAN IDENTIFYING WHAT
 WINDOW IS #1 IS THIS CONCRETE, FILLED
 CELL OR WOOD?
  
 10) NONE OF THE PRODUCT TESTING REPORTS
 CAN BE USED SINCE THE WINDOW NOR DOOR
 PRESSURES ARE GIVEN, THE NOTE COMPONENTS
 & CLADDING INDICATE A -68.1 PRESSURE????
 THE PRODUCT TESTING PRESSURES ARE TO LOW
  
 11)SBCCI REPORT 2139, SPECIFY WHICH
 DOOR ASSEMBLY SHALL BE USED.
 HIGHLIGHT MODEL NUMBER.
  
 12) NOTE 7 DOES NOT LIST NAILING REQUIRE
 MENTS FOR ZONE 3, WHICH APPLIES TO THE
 GABLE ENDS.CITY AMENDMENTS 2306.1.REVISE
 NOTE # 7.
  
 13) SHEET# 1 "ROOF NOTES"-8 REFERS TO
 " C & SE" ZONES, PLEASE EXPLAIN??
  
 14) SHEET # 1 INDICATES (2) SECTION A'S
 ONE A FRONT VIEW THE OTHER A SIDE VIEW?
  
 15) SHEET 2 OF 7 FOUNDATION DETAIL FOR
 SHOWER THIS IN THE 2 STORY SECTION OF
 THE BUILDING THE DETAIL HAS NO DIMENSION
 INDICATING HEIGTH OR WIDTH AS DEPICTED
 IT ISN'T 20" WIDE.
  
 16) THE SAME SHEET FOUNDATION DETAIL# 12
 INDICATES THE USE OF A 6" SLEEVE, WHAT
 ISN'T GIVEN IS THE MINIMUM HEIGTH OF
 19 1/2 " EXT DIA.X 3. 1907.3.5(1)
  
 17)2804.4.1 FACTORY-BUILT CHIMNEYS
 FACTORY BUILT CHIMNEYS SHALL BE LISTED
 AND SHALL BE INSTALLED IN ACCORDANCE
 WITH THE CONDITIONS OF THE LISTING, AND
 MANUFACTURER'S INSTRUCTION.
  
 18)CHIMNEYS FOR THE USE WITH FACTORY-
 BUILT FIREPLACES SHALL MEET THE
 REQUIREMENTS OF UL 127.
  
 19)2806.1.2 FACTORY BUILT FIREPLACES
 SHALL BE TESTED IN ACCORDANCE WITH AND
 MEET THE REQUIREMENTS OF UL 127.
  
 20)2810 FRESH AIR INTAKES, FRESH AIR
 INTAKESSHALL BE SCREENED WITH A CORRO-
 SION RESITANT MATERIAL NOT LARGER THAN
 1/2 INCH MESH. FRESH AIR INTAKES SHALL
 NOT BE TAKEN FROM A LOCATION CLOSER THAN
 10 FT FROM ANY CHIMNEY OR VENT OUTLET OR
 SANITARY SEWER VENT OUTLET, UNLESS SUCH
 VENT IS NOT LESS THAN 24" ABOVE THE
 FRESH AIR VENT. FRESH AIR INTAKE VENTS
 LOCATED ON THE ROOFS WILL BE PROPERLY
 MARKED WITH A UNIVERSAL MARKING,
 ***"INTAKE"***, PERMANETLY ATTACHED.
 SEE 705.1.1.4 FOR FIRE PROTECTION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW