2002-06-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) A DRINKING FOUNTAIN AND SERVICE SINK
 ARE REQUIRED PER TABLE 403.1. PLEASE IN-
 DICATE IF THESE ARE PROVIDED.
 2) SHT A-1 PROVIDE MANUFACTURE INFORMAT-
 ION FOR INSTA HOT AND WATER FILTER UNDER
 KITCHEN SINK. INSTA HOT MUST SHOW LIST-
 ING FROM AN APPROVED TESTING AGENCY, AND
 THE WATER FILTER MUST BE NSF APPROVED.
 3) SHT P-1 WATER RISER DIAGRAM. SHOW
 WATER HAMMER ARRESTOR NEAR FIXTURE IN
 AN "EFFICTIVE RANGE" NOT AT TOP OF DROP
 AS SHOWN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377