2002-08-07 00:00:00 | BUILDING DENIED |
| |
| 1) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) PROVIDE A SOIL BEARING REPORT PER |
| CITY AMENDMENTS TO THE 2001 FBC 1804.2.2 |
| |
| 3) THE CONDITIONED AREA ON THE PLANS IS |
| DIFFERENT FROM THE AREA LISTED ON THE |
| ENERGY CALC. FORM. PLEASE CORRECT. |
| |
| 4) THE AREA UNDER ATTIC LISTED ON THE |
| ENERGY CALCS. DOES NOT INCLUDE THE BONUS |
| ROOM. THE AREA OF THE WOOD FRAME WALLS |
| OF THE BONUS ROOM ADJACENT TO THE |
| UNCONDITIONED GARAGE IS NOT LISTED ON |
| THE ENERGY CALC. FORM. PLEASE CORRECT. |
| |
| 5) THE PRODUCT APPROVALS SUBMITTED FOR |
| THE DOUBLE DOORS AT THE FRONT ENTRY ARE |
| NOT LEGIBLE. PLEASE SUBMIT CLEAR COPIES. |
| |
| 6) THE PRODUCT APPROVALS SUBMITTED FOR |
| THE SINGLE HUNG WINDOWS ARE NOT |
| ACCEPTABLE. THE COVER SHEET DOES NOT GO |
| WITH THE OTHER PAGES, WHICH ARE EXPIRED. |
| PLEASE SUBMIT CURRENT AND COMPLETE |
| PRODUCT APPROVALS. |
| |
| 7) FIREBLOCKING IS REQUIRED AT THE TOP |
| OF THE STAIR RUN. PLEASE INDICATE THIS |
| ON DETAIL 2 OF SHEET A-7. |
| |
| 8)THERE ARE DISCREPANCIES IN THE OPENING |
| SIZES BETWEEN THOSE LISTED ON THE KEY |
| PLAN AND THE INSTALLATION SCHEDULE AND |
| THE ARCHITECTURAL PLANS. PLEASE REVISE |
| SO THAT ALL LIST THE SAME SIZES FOR THE |
| SAME OPENING. |
| |
| 9) THE ARE SEVERAL SHEETS MISSING FROM |
| THE PLANS. PLEASE SUBMIT (2) COMPLETE |
| SETS OF PLANS. (A-3,A-4,A-5) |
| |