Date |
Text |
2002-07-03 00:00:00 | CHECKLIST: |
| 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| 2-REVISE ATTIC ACCESS SIZE ON KEY NOTE |
| #7. SEE SEC. 2309.6 FBC 2001. 36"MIN. |
| 3-CLARIFY SIZE OF EGRESS WINDOWS. 34SH |
| WINDOW DON'T PROVIDE 24" MIN. CLEAR |
| HEIGHT OPENING. ARE THESE CUSTOM MADE |
| WINDOWS?. SECTION 1005.4.4 FBC 2001. |
| 4-CLARIFY STAIRS RATIO. SEE SHEET A-5. |
| **NOTE: SEE OTHER COMMENTS ON PLANS AND |
| BRING BACK REVIEWED SET. |
| 5-SPECIFY FIREBLOCKING MATERIALS AND |
| LOCATION AT STAIRS. SEC. 2305.1.4 FBC |
| 6-SPECIFY DRAFSTOPPING LOCATION AND |
| MATERIAL AT 2ND FL FRAMING PLAN. |
| SEC. 2305.2.2 FBC 2001. |
| 7-SPECIFY FIRECUTS AT MASONRY WALL AS |
| REQUIRED BY SEC. 2305.4 FBC 2001. |
| 8-PROVIDE SOIL TEST REPORT. |
| 9-STORM SHUTTERS: |
| A)PROVIDE COMPLETE INSTALLATION SCHEDULE |
| AND KEY PLAN. SEE CITY SAMPLE. |
| B)CLEARLY INDICATE ON DRAWINGS SPECIFIC |
| MOUNTING CONDITIONS & ANCHOR TYPE AND |
| SPACING TO BE USED ACCORDING TO THE |
| MEAN ROOF HEIGHT, DESIGN PRESSURES, |
| EDGE DISTANCE, PANEL SPAN, CONNECTION |
| TYPE AND STRUCTURE TO BE ATTACHED TO |
| (CONCRETE BLOCK OR CONCRETE) |
| 10-PROVIDE PRODUCT APPROVAL FOR: |
| A)DOUBLE ENTRY DOORS AS SHOWN ON PLANS. |
| B)COMPLETE PAN AMERICAN WINDOW MULLION |
| PRODUCT APPROVAL. |
| C)ARCHED WINDOW NEED LEGIBLE DRAWINGS. |
| AND SEE SIZES SHOWN ON PLANS. |
| D)SINGLE HUNG WINDOWS PRODUCT APPROVAL |
| IS NOT GOOD. FIRST PAGE DOESN'T MATCH |
| THE REST OF PRODUCT APPROVAL. |
| 11-PROVIDE UPDATED ORIGINAL LETTER FOR |
| MASONRY USED ADDRESSED TO THE CITY OF |
| W.P.B. AND THE CONTRACTOR AND SPECIFY |
| THE PROJECT. |
| 12-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR |
| FIXED WINDOWS AS REQUIRED ON THE |
| SUBMITTED PRODUCT APPROVALS. |
| 13-SHEET C-1: LOAD CALCULATIONS IS |
| MISSING THE INTERNAL PRESSURE |
| COEFFICIENT AS REQUIRED ON SECTION |
| 1606.1.7 FBC 2001. |
| 14-PROVIDE COMPLETE GABLE END DETAIL. |
| SEE SECTION 2117.1.1 FOR CONTINUITY OF |
| GABLE END WALL. |