2004-04-12 00:00:00PRODUCT APPROVAL SUBMITTAL
 ***CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE NOA IS NO LONGER IN THE
 PACKAGE THAT WAS PREVIOUSLY SUBMITTED
 FOR THE MECHANICAL ROOF.ARE YOU USING
 THE GUTTER ROOF PRODUCT AT THE
 MECHANICAL ROOF?IT IS MARKED GUTTER
 ROOF.
  
 2.)A REQUEST WAS MADE FOR THE ORIGINAL
 SIGNED AND SEALED COVER LETTER AND TEST
 REPORT, SEE PREVIOUS LIST #3.THIS
 IS NO LONGER IN THE PACKAGE, ONLY
 PRODUCT DATA.
  
 3.)REGARDING SERIES 35H (MD)
 STOREFRONT DOOR, STEELCRAFT DOORS,
 SERIES 800 SERVICE DOOR, SERIES 2000 SGD
 THE ZONE 5 PRESSURES EXCEED PRODUCT
 LIMITATIONS.ARE THESE TO BE INSTALLED
 IN ZONE 4 ONLY?WHAT WILL BE USED IN
 ZONE 5?
  
 4.)THE STEELCRAFT DOOR IS TO BE
 TESTED TO ASTM E330-84, FBC35.PROVIDE
 A SITE SPECIFIC OR SUBMIT A TEST REPORT
 THAT COMPLIES WITH FBC.ALSO SEE
 PREVIOUS NOTE IN REGARDS TO THE
 PRESSURES.
  
 CC:DON NEELY
2004-03-23 00:00:00****CORRECTIONS****
 PRODUCT APPROVAL SUBMITTAL
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)NOA 030421.04, SIX STORY GUTTER
 ROOFS - MAX DESIGN PRESSURE IS 97.5,
 DESIGN PRESSURE FOR SIX STORY ROOF
 IS 146.2.SEE GENERAL LIMITATION #9.
  
 2.)NOA 030212.06, THREE STORY
 MECHANICAL ROOF - MAX DESIGN PRESSURE IS
 -75, DESIGN PRESSURE FOR THREE STORY IN
 ZONE 2 IS 88.3.ENHANCED FASTENING,
 RATIONAL ANALYSIS OR EXTRAPOLATION
 IS TO BE DONE BY THE DESIGNER OF
 RECORD.SEE GENERAL LIMITATION #7.
  
 3.)JOHNS MANVILLE MODIFIED BITUMEN
 TEST REPORT - SUPPLY AN ORIGINAL
 SIGNED AND SEALED COVER LETTER FROM
 ATLANTIC CARRIBEAN. (FOR ONE AND THREE
 STORY ROOFS)
  
 THE FOLLOWING ROOF PRODUCT APPROVAL
 SUBMITTALS ARE APPROVED CONDITIONALLY
 SUBJECT TO REVIEW BY DESIGNERS OF
 RECORD AS PER COMMENT ON MODIFIED
 BITUMEN ROOFING SHOP DRAWINGS:
 ULTRAGUARD PVC-LIGHTWEIGHT CONCRETE DE
 BASE SHEET ATTACHMENT CALCS, 1 STORY
 BASE SHEET ATTACHMENT CALCS, 3 STORY
 ALTUSA S
 POLYFOAM
 TILE SPECS, SYSTEM B
 TILE UNDERLAYMENT FASTENER SPACING
 TILE ATTACHMENT CALCS
  
 4.)AS PER CONVERSATION WITH BOB
 LUTHER, WINDOW DESIGN PRESSURES WERE
 NOT ON THE PLAN AND WERE PROVIDED AS
 A SEPARATE SUBMITTAL.PROVIDE A COPY
 FROM THE ENGINEER SO THAT THE OTHER
 PRODUCTS SUBMITTED CAN BE REVIEWED.
  
  
 ROOF SUBMITTAL #07A-05-07552-0
 SIX STORY MODIFIED ROOF DATA
  
 ROOF SUBMITTAL #07A-04-07522-0
 1 & 3 STORY MODIFIED ROOF DATA
  
 PLEASE RESUBMIT AFTER APPROVAL OF
 SYSTEM (TEST REPORTS) BY DESIGNER OF
 RECORD.
  
  
  
  
  
 CC:DON NEELY