Plan Review Notes
Plan Review Notes For Permit 02060290
Permit Number 02060290
Review Stop B
Sequence Number 1
Notes
Date Text
2002-07-12 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02060290
 ADD:707 39TH ST (REAR UNIT)
 CONT: KENCUO DEV CORP INC
 TEL: 784-8618
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)ALL INFORMATION, DRAWINGS, SPECIF-
 ICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE & TELEPHONE
 NUMBER OF THE PERSON RESPONSIBLE FOR
 THE DRAWING OF THE PLANS, CITY AMEND
 104.2.1.
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED, NOTES
 INDICATE THE 2002 FL BLDG CODE, CURRENT
 EDITION 201 FL BLDG CODE.
  
 4) PROVIDE 2 CURRENT COPIES OF SIGNED &
 SEALED SURVEYS WITH PROPOSED IMPROVEMENT
 TO BE COMPLETED.
  
 5) EXISTING GARAGE HAS TO MAINTAIN THIS
 USAGE PER THE CITY ZONING CODE, ONE END
 MAY BE BLOCKED IN, PROVIDE (2) COPIES OF
 CURRENT PRODUCT TESTING REPORT FOR THE
 OVERHEAD DOOR.SBCCI OR DADE COUTNY
 REPORTS ARE ACCEPTED.
  
 6)411.2.8. OPENINGS FROM A PARKING
 GARAGE DIRECTLY INTO A ROOM FOR SLEEPING
 PURPOSES SHALL NOT BE PERMITTED.
  
 7)905.2.1 APPROVED SINGLE-STATION OR
 MULTIPLE STATION SMOKE DETECTORS SHALL
 BE INSTALLED IN ACCORDANCE WITH NFPA 72,
 CHAPTER 2, WITHIN EVERY DWELLING UNIT
 WITHIN AN APARTMENT HOUSE, CONDOMINIMUM,
 OR TOWNHOUSE AND EVERY GUEST OR SLEEPING
 ROOM IN A MOTEL, HOTEL, OR DORMITORY &
 SLEEPING ROOMS IN RESIDENTIAL CARE/
 ASSISTED LIVING OCCUPANCIES. WHERE MORE
 THAN ONE DETECTOR IS REQUIRED TO BE
 INSTALLED WITHIN INDIVIDUAL DWELLING
 UNIT, THE DETECTOR SHALL BE WIRED IN
 SUCH A MANNER THAT THE ACTUATION OF ONE
 ALARM WILL ACTIVATE ALL THE ALARMS IN
 THE INDIVIDUAL UNIT.
  
 8) INDICATE THE BEDROOM WINDOW SIZE FOR:
 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 9) INDICATE THE SIZE WINDOW OPEN AREA
 FOR BATH ROOM, OR IS MECHANICAL VENTILAT
 ION TO BE REQQUIRED? 1203.4.2/1203.5.
  
 10) 1204.1 FIXTURES, MISSING LAV IN BATH
 ROOM. SEE PLUMB 403.1 TABLE.
  
 11)DOES THE TUB INCLUDE A SHOWER UNIT?
 1204.4
  
 12) CHAPTER 13, RESIDENTIAL BUILDING
 COMPLIANCE, FORM 600 3.C IS TO BE USED
 FOR RESIDENTIAL RENOVATIONS 600 SQ FT OR
 LESS UNDER AIR.THIS IS A PERSCRIPTIVE
 METHOD WHERE TABLES 6C-1 & 6C-2 APPLY.
  
 13)1503.3 COPING. PARARET WALLS SHALL
 BE PROPERLY COPED WITH NONCOMBUSTIBLE
 MATERIALS OF A WIDTH NO LESS THAN THE
 THICKNESS OF THE PARAPET WALL.
  
 14) 1503.4.4 PROTECTION AGAINST DECAY &
 TURMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 15) FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 16) FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 17)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 A) OVERHEAD GARAGE DOOR
 B) WINDOWS
 C) MULLIONS
 D) EXTERIOR DOORS
 E) STORM SHUTTERS
  
 18)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 19) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 20) 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY. PLANS DO NOT INDICATE THE
 SIZE OF FRAMING MEMBERS, SPANS, TYPE OF
 DEVICE TO BE USED TO RESIST UPLIFT LOADS
 NOR GRAVITY LOADS. THERE IS NO INFORMA-
 TION ON THE TEMPORARY BRACING WHEN THE
 ROOF FRAMING IS REPAIRED. NO INFORMATION
 ON THE TIMBERS TO BE SISTERED IN AS TO
 LAPS NAILING SIZE OR PATERNS, ETC.NO
 INFORMATION AS TO EXTERIOR WALLS, WALL
 SECTIONS ROOF FRAMING DETAILS, FOR CBS
 AND FRAME WALLS (GARAGE).
  
 21) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 22) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 23) 2304.5 CLEARENCE BETWEEN WOOD SIDING
 & EARTH ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6" EXCEPT WHERE
 SIDING, SHEATHING AND FRAME WALL ARE OF
 APPROVED DURABLE WOOD OR APPROVED PRE-
 SERVATIVE TREATED WOOD. (GARAGE WOOD
 WALLS). WHAT TYPE OF EXTERIOR FINISH?
  
 24) POSSIBLE TABLE 600 ISSUES THERE
 IS NO REAR ELEVATION, INDICATING THE
 AMOUNT OF OPENINGS SIZES INCLUDING WHICH
 END OF GARAGE IS TO BE CLOSED?
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026