Notes
Date Text
2002-09-04 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02060289
 ADD: 707 39TH ST (FRONT BUILD)
 CONT: KENACO DEV CORP INC
 TEL: (561)784-8618
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 1) WHAT OCCUPANCY USE WILL THIS BE?
 A) R-3 SINGLE FAMILY OCCUPANCY
 B) R-3 ROOMING HOUSE (NOT TRANSIENT)
 C) R-2 ROOMINGHOUSE (TRANSIENT)
 D) R-1 BOARDING HOUSE (TRANSIENT)
  
 2) AS STATED IN THE OPENING STATEMENT,
 LIST WORK TO BE ACCOMPLISHED ON THE
 INTERIOR, AS WELL AS EXTERIOR.
  
 3) 3401.7.2 REPAIRS AND ALTERATIONS,
 AFTER AN ACCURATE DESCRIPTION OF WORK
 THAT SHALL BE COMPLETED UNDER THIS PER-
 MIT ATRUE ASSESSMENT OF THE DOLLAR
 VALUE CAN BE DERIVED FOR WORKTO BE PER-
 MITTED. THIS SECTION OF THE CODE DETER-
 MINES AS TO WHAT SHALL BE REQUIRED TO BE
 BROUGHT UP TO CODE BY THE PERCENT OF
 WORK ACCOMPLISHED (DOLLAR VALUE) VS THE
 VALUE OF THE EXISING BUILDING.
  
 4) 1203.2.5 KITCHENS SHALL BE NO LESS
 THAN 7 FT IN ANY DIRECTION.
  
 5) 1203.4.1 TOLIET ROOMS SHALL NOT OPEN
 DIRECTLY INTO A ROOM USED FOR THE PREP-
 ARATION OF FOOD FOR SERVICE TO THE
 PUBLIC. OCCUPANCY USE SHALL DETERMINE
 IF THIS SECTION IS APPLICABLE.
  
 6) MISSING PRODUCT TESTING REPORTS FOR
 ALL EXTERIOR DOORS & GLAZED OPENINGS.
 2 SETS OF PRODUCT TESTING REPORTS ARE
 REQUIRED FOR EACH BUILDING, SINCE THEY
 ARE UNDER SEPERATE PERMIT!!!!!!!
  
 7) 1007.4.2 STAIRS SHALL HAVE FLOORS OR
 LANDINGS AT DOOR OPENINGS. MISSING AT
 THE FRONT ENTRY AND FIRST FLOOR PROPOSED
 KITCHEN.
  
 8) 1007.5.1 HANDRAILS REQUIRED FOR
 STAIRWAY, GRIPPING SURFACES SHALL BE
 CONTINUOUS, WITHOUT INTERRUPTION BY
 NEWEL POST OR OTHER OBSTRUCTIONS.
  
 9) 1007.5.5 HANDRAILS SHALL EXTEND AT
 LEAST 12" HORIZONTALLY BEYOND THE TOP
 RISER OF A FLIGHT . AT THE BOTTOM, THE
 HANDRAIL SHALL BE CONTINUE TO THE SLOPE
 FOR A DISTANCE OF THE DEPTH OF ONE TREAD
 FROM THE BOTTOM RISER. EXCEPTION,
 HANDRAILS IN A DWELLING UNIT. OCCUPANCY
 SUB-CLASSIFICATION SHALL DETERMINE!
  
 10) UPPER FLOOR PLAN IS THE DETAIL FOR A
 "ALTERNATE KITCHEN" TO BE USED FOR THE
 SECOND FLOOR MAKING 2 KITHENS FOR THIS
 BUILDING?
  
 PLANS ARE NOT THROUGH ENOUGH TO DO A
 COMPLETE REVIEW. PLEASE ADDRESS THE
 ABOVE ISSUES. BECAUSE OF NOT ANSWERING
 THE SAME COMMENTS FROM THE FIRST REVIEW
 ADDITIONAL COMMENTS MAY APPEAR FOR THE
 FIRST TIME ON THE NEXT REVIEW!!!!
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412