2003-01-27 00:00:00CHECKLIST FOR PROVISO SUBMITTAL:
 1-ENGINEERING CALCULATIONS SHOW THAT
 WOOD COLUMNS (P1) ARE NOT STRUCTURALLY
 ADEQUATE. SHEET S-1 SHOWS WOOD COLUMN
 P1 AT DEN AREA. CLARIFY AND REVISE AS
 REQUIRED AND PROVIDE CERTIFICATION
 THAT STEEL COLUMN WAS INSTALLED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 2-PROVIDE SOIL TEST REPORT. THERE'S NONE
 SUBMITTED FOR THE CITY FILES.
 3-STORM SHUTTERS: A)PROVIDE COMPLETE
 SBCCI PRODUCT APPROVAL REPORT #2229.
 B)CLEARLY MARK ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 C)CHECK DESIGN PRESSURES SPECIFIED ON
 PLANS AND THOSE SPECIFIED ON INSTALLA-
 TION SCHEDULE.
 D)PROVIDE INSTALLATION SCHEDULE AND KEY
 PLAN THAT MATCH ACTUAL PLANS SUBMITTED
  
 4-SINGLE HUNG WINDOWS PRODUCT APPROVAL
 IS EXPIRED.
 5-ENTRY DOOR PRODUCT APPROVAL NEED FRONT
 PAGE TO HAVE DADE COUNTY LOGO AND THE
 DRAWINGS STAMPED WITH THE RENEWAL # AS
 REQUIRED BY DADE COUNTY.