2002-06-26 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) INDICATE ON THE PLANS THAT THE WELDED
 WIRE MESH WILL BE SUPPORTED. SEE FBC
 SEC. 1909.3.
  
 3) ON SHEET 2 THE REINFORCED FILLED CELL
 IS NOT INDICATED AT ONE SIDE OF THE
 BATHROOM WINDOW.
  
 4) CLARIFY THE FOOTING SIZE AND
 REINFORCEMENT FOR THE TWO COLUMNS AT THE
 FRONT ENTRY. INDICATE THE SIZE AND
 REINFORCEMENT FOR THE COLUMNS AT THE
 ENTRY AND COVERED LANAI.
  
 5) INDICATE WHERE THE BLOCK ENTRY COLUMN
 SHOWN ON SHEET 2 WILL BE LOCATED.
  
 6) THE IDENTIFICATION MARKS GIVEN FOR
 THE WINDOWS ON SHEET 3 DO NOT ALL
 CORRESPOND WITH THOSE LISTED IN THE
 WINDOW SCHEDULE. PLEASE CORRECT.
  
 7) INDICATE THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES FOR ALL EXTERIOR
 OPENINGS.
  
 8) PLEASE CORRECT THE INTERNAL PRESSURE
 COEFFICIENT LISTED ON SHEET 6. IT IS +
 OR - .18 FOR AN ENCLOSED STRUCTURE.
  
 9) NOTE 8 OF THE ROOF NOTES ON SHEET 6
 REFERS TO ZONES C AND SE. PLEASE
 IDENTIFY THESE ON ON THE PLANS.
  
 10) NOTE 7 DOES NOT LIST NAILING
 REQUIREMENTS FOR ZONE 3, WHICH APPLIES
 TO THE GABLE END. CITY AMENDMENTS 2306.1
 PLEASE REVISE.
  
 11) THE ROOF DESIGN CRITERIA IS LISTED
 ON SHEET 6. PLEASE INDICATE THE DESIGN
 CRITERIA THAT WAS USED TO DESIGN THE
 REST OF THE MAIN WIND-FORCE RESISTING
 SYSTEM.
  
 12)PLEASE PROVIDE CLEAR TIES FROM SHEETS
 1-6 OF THE PLANS TO THE DETAILS AND
 SECTIONS ON SHEETS A AND B.
  
 13) PLEASE INDICATE WHICH STORM PANEL
 SYSTEM OR COMBINATION OF THEM WILL BE
 USED. THE MASTER BEDROOM SLIDING GLASS
 DOOR IS NOT LISTED ON THE EASTERN METAL
 SUPPLY KEY PLAN OR SCHEDULE. THE SITE
 SPECIFIC ENGINEERING FORM ALL AMERICAN
 IS REQUIRED TO BE REVIEWED AND APPROVED
 BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE. HIS SIGNATURE AND RAISED
 SEAL IS REQUIRED ON THE FORM.
  
 IF YOU HAVE A QUESTION PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202