Date |
Text |
2002-06-17 00:00:00 | CHECKLIST: |
| 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| 2-REVISE SIZE OF ATTIC ACCESS. KEY NOTE |
| #7.36" MIN. SIZE. SEC 2309.6 FBC. |
| 3-CLARIFY SIZE OF EGRESS WINDOWS. 34SH |
| WINDOWS ARE 48" TYPICALLY 48" HIGH AND |
| WILL NOT HAVE 24" CLEAR HEIGHT OPENING |
| AS REQ'D BY SECTION 1005.4.4 FBC 2001. |
| 4-REVISE STAIRS RATIO. SEE SECTION |
| 1007.3.1 (EXCEPTION #1). |
| 5-SEE COMMENTS ON PLANS AND BRING BACK |
| REVIEWED SET AFTER CORRECTIONS ARE |
| DONE TO ORIGINAL DRAWINGS. |
| 6-PROVIDE ATTIC ACCESS AT FRONT PART OF |
| GARAGE ROOF AND AT MORNING ROOF IF |
| THERE IS A CLEAR ATTIC SPACE NOT LESS |
| THAN 24" SEC. 2309.6 FBC 2001. |
| 7-SPECIFY FIREBLOCKING MATERIALS AND |
| LOCATION AT STAIRS. SEC. 2305.1.4 FBC. |
| 8-SPECIFY DRAFSTOPPING LOCATION AND |
| MATERIAL AT 2ND FL. FRAMNG PLAN AS |
| REQUIRED BY SEC. 2305.2.2 FBC 2001. |
| 9-SPECIFY FIRECUTS AT MASONRY WALL AS |
| REQUIRED BY SEC. 2305.4 FBC 2001. |
| 10-PROVIDE SPECIFICATIONS FOR SOIL AND |
| FOOTING PROTECTION WHEN IMPACTED BY |
| WATER FROM ROOF VALLEYS. SEE SECTION |
| 1804.1.6 FBC 2001. |
| 11-PROVIDE SOIL TEST REPORT. |
| 12-DESIGN JOINTS AT CONCRETE SLAB. SEC. |
| 1909.3 FBC 2001. (OR SPECIFY SUPPORTS) |
| 13-STORM SHUTTERS: |
| A)PROVIDE COMPLETE INSTALLATION SCHEDULE |
| & KEY PLAN. SEE CITY SAMPLE. |
| B)CLEARLY INDICATE ON DRAWINGS SPECIFIC |
| MOUNTING CONDITIONS & ANCHOR TYPE & |
| SPACING TO BE USED ACCORDING TO THE |
| DESIGN PRESSURES, MEAN ROOF HEIGHT, |
| EDGE DISTANCE, CONNECTION TYPE, PANEL |
| SPAN & STRUCTURE TO BE ATTACHED TO. |
| 14-PROVIDE PRODUCT APPROVAL FOR: |
| A)DOUBLE ENTRY DOORS AS SHOWN ON PLANS. |
| B)COMPLETE PAN AMERICAN WINDOW MULLION |
| PRODUCT APPROVAL (NOT LAWSON, SINCE |
| WINDOWS USED ARE BY PAN AMERICAN) |
| C)ARCHED WINDOWS NEED LEGIBLE DRAWINGS. |
| 15-PROVIDE UPDATED ORIGINAL LETTER OF |
| MASONRY TYPE TO BE USED. LETTER TO |
| BE ADDRESSED TO THE CITY OF WEST PALM |
| BEACH AND ADDRESSING SPECIFIC JOB. |
| 16-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR |
| FIXED WINDOWS AS REQ'D ON PRODUCT |
| APPROVAL SUBMITTED. |