2002-05-23 00:00:00 | DENIED |
| REFERENCE: FBC-2001 424.2 SWIMMING POOLS |
| |
| A) PLEASE ADJUST YOUR NOTES, DETAILS, OR |
| SUBMITTALS TO REFLECT THE FOLLOWING IN- |
| FORMATION REQUIRED FOR PLAN REVIEW. |
| 1) COMPLY WITH FBC-2001 SEC 424.2 |
| PRIVATE SWIMMING POOLS. |
| 2) FBC-2001 SEC 424.2.6.1 ENGINEERING |
| DESIGN, CONSTRUCTION AND WORKMANSHIP. |
| ANSI/NSPI-4 92. AND NSPI-5 |
| 4) FBC-2001 SEC 424.2.6.6 ENTRAPMENT |
| PROTECTION FOR SUCTION INLETS. (DETAIL) |
| 5) FBC-2001424.2.6.6.2 SHOW COMPLIANCE |
| WITH ANSI/ASME A112.19.8M. PROVIDE MODEL |
| NUMBER AND MANUF INFO FOR VAC LOCK IF |
| VACUUM LINE. (DETAIL/NOTE/OR SUBMITTAL) |
| 6) VENT - VENT SHALL BE VENTED TO ATMOS- |
| PHERE IN A MANNER THAT THE VENT WILL NOT |
| BE BLOCKED BY INFESTATION, DEBRIS BUILD |
| UP, OR MICROBIOLOGICAL CONTAMINATION. |
| LABLE VENT: "POOL SAFETY DEVICE- DO NOT |
| HANDLE. (ADD TO NOTES) |
| 7) FBC-2001 424.2.7.2 PUMPS AND EQUIP- |
| MENT SHALL BE MOUNTED ON A SUBSTANTIAL |
| BASE IN A MANNER THAT WILL ELIMINATE |
| STRAIN ON PIPING. SLAB SHALL BE A NOMIN- |
| AL 4" THICK. (DETAIL) |
| 8) FBC-2001 424.2.9 WATER SUPPLY, LOCAL |
| ORD. #2853-95, BACKFLOW REQUIRED ON |
| WATER SERVICE. (ADD TO NOTES) |
| 9) FBC-2001 424.2.12.1 PRESSURE TESTS. |
| PER MANUFACTURE RECOMMENDATIONS, NO AIR |
| TEST SHALL BE APPROVED FOR PVC PIPE AND |
| FITTINGS. (ADD TO NOTES) |
| 1O) FBC-2001 424.2.13.2JOINTS AND CON- |
| NECTIONS, FBC PLMG SEC 605.21, PURPLE |
| PRIMER REQUIRED ON PVC PIPING. (ADD TO |
| NOTES) |
| 11) ALL SHEETS OF A SIGNED AND SEALED |
| SET OF PLANS SHALL BE SIGNED AND SEALED. |
| 8-1/2" X 11" SHEET WITH TITLE BLOCK NOT |
| SEALED AND DATED. |
| |
| REVIEW BY KEN STEVENS |