Date |
Text |
2002-05-14 00:00:00 | BUILDING DENIED |
| |
| 1) THE 2001 FBC SECTION 1606.1.7 |
| REQUIRES THE FOLLOWING INFORMATION TO BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS: |
| - BASIC WIND SPEED, MPH. |
| - WIND IMPORTANCE FACTOR(1) AND BUILDING |
| CATEGORY. |
| - WIND EXPOSURE- IF MORE THAN ONE WIND |
| EXPOSURE IS USED THE WIND EXPOSURE AND |
| APPLICABLE WIND DIRECTION SHALL BE |
| INDICATED. |
| - THE APPLICABLE INTERNAL PRESSURE |
| COEFFICIENT |
| - COMPONENTS AND CLADDING. THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF, TO BE |
| USED FOR THE DESIGN OF EXTERIOR |
| COMPONENT AND CLADDING MATERIALS NOT |
| SPECIFICALLY DESIGNED BY THE REGISTERED |
| DESIGN PROFESSIONAL. |
| THE DESIGN CERTIFICATION FORM THAT WAS |
| SUBMITTED IS NO LONGER ACCEPTABLE. IT |
| ALSO WAS BASED ON THE 97 SBC WHICH WAS |
| REPLACED BY THE 2001 FBC ON 3-1-02. |
| |
| 2)PROVIDE (2) CURRENT AND COMPLETE |
| COPIES OF SBCCI OR METRO-DADE PRODUCT |
| APPROVALS FOR: |
| - ROOFING MATERIAL |
| OR A SEPARATE PERMIT WILL BE REQUIRED |
| WITH ADDITIONAL FEES. |
| THE OWNER BUILDER IS REQUIRED TO SIGN |
| THE BACK OF THE APPLICATION ON THE ROOF- |
| ING CONTRACTOR LINE IF THEY WISH TO |
| INCLUDE THE ROOFING WITH THE PERMIT. |
| PLEASE INFORM THE PERMIT CLERK SO THAT A |
| PERMIT NUMBER CAN BE GENERATED. |
| |
| IF YOU HAVE ANY QUESTIONS PLEASE CALL: |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)659-8096 EXT.8202 |