2002-05-17 00:00:00THE NORANDEX WINDOW DESIGN SHEET CITES
 THE 1997 SBCCI CODE WHICH HAS BEEN
 SUPERCEDED BY THE FBC 2001.PLEASE
 REVISE AS NECESSARY AND ENSURE
 COMPLIANCE WITH THE FBC.
  
 SHUTTERS FOR THE SECOND STORY ARE NOT A
 PRACTICAL APPLICATION.PLEASE PROVIDE
 AN ALTERNATE HURRICANE MISSILE IMPACT
 RESISTANT METHOD.SEE THE ATTACHED
 CITY IMPLEMENTATION STANDARD.
  
 SHEET 11 SECTION F, WRONGLY DEPICTS THE
 FRT PLYWOOD ROOF SHEATHING TO BE
 INSTALLED FOUR FEET FROM THE CENTER
 LINE OF THE PARTY WALL.FBC 704.4.2
 (2) PROVIDES FOR THE PROTECTION TO
 OCCUR FROM EACH "SIDE" OF THE WALL.
 PLEASE REVISE AS NECESSARY.
  
 SHEET 11 SECTION B SHOWS A FOOTING DEPTH
 OF 8" THAT SHOULD BE 12" IN ACCORDANCE
 WITH FBC 1804.1.3.
  
 SHEET 11 SECTION C IS NOT CLEAR AS TO
 HOW THE OVERHANG OUTLOOKER WILL BE
 CONNECTED AND THE FEASIBILITY OF THE
 VENTING IN THE SOFFIT.
  
 SBCCI REPORT #9755 FOR THE AMARR GARAGE
 DOOR IS NOT A CURRENT LISTING WITH SBCCI
 PLEASE PROVIDE A CURRENT OR ALTERNATE
 LISTING.